Skip to main content
Siemens 5SV3645-6 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV3645-6 RCCB, 4-pole Type A, 125 A 300 mA 400 V

MPN5SV3645-6
Active

Siemens 5SV3645-6 RCCB, 4-pole, Type A, In: 125 A, 300 mA, Un AC: 400 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SV3645-6 — Specifications
ParameterValue
Group codeP310
Product group5511
Product classB: return restricted, please contact your Siemens partner/contact
SeriesRCCBs
Export control regulationsAL : N / ECCN : EAR99
Compliance with the substance restrictions according to RoHS directiveSince: 02-06-23

Product details

The Siemens 5SV3645-6 is a 4-pole residual current circuit breaker (RCCB) from the RCCBs family, rated 125 A with a 300 mA sensitivity, Type A, for 400 V AC systems. Type A detection means it trips on sinusoidal AC residual currents and on pulsating DC residual currents up to 6 mA — the standard for circuits feeding single-phase rectifiers, switching power supplies, or variable-speed drives where the fault waveform isn't a clean sine. The 300 mA rating suits it for fire protection or general shock prevention in distribution boards where nuisance tripping from leakage on long cable runs or filter caps needs to be avoided.

RoHS compliance is confirmed since 02 June 2023; REACH candidate-list information is available per Article 33. Export control is straightforward — AL: N, ECCN: EAR99 — no special license required for most destinations.

Integration Notes

The 125 A frame means incoming cable and busbar sizing should match — this is a main or heavy-feeder RCCB, not a branch-circuit unit. Packaged singly (1 piece), dimensions 78 x 97 x 85 mm — verify panel cutout depth before mounting.

Frequently asked questions

What is the 5SV3645-6 used for?

It is a 4-pole Type A residual current circuit breaker rated 125 A, 300 mA, 400 V AC — used for earth-fault protection in distribution boards where the load includes electronics that produce pulsating DC fault currents.

What compliance documentation is available for the 5SV3645-6?

RoHS compliance is confirmed since 02 June 2023; REACH Article 33 duty-to-inform information is available. Export control is AL: N / ECCN: EAR99.

How can I get current pricing and availability for the 5SV3645-6?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN
5SV3645-6