Siemens 5SV3646-3 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV3646-3 SENTRON RCCB, 4P, 63A, 300mA, Type F

MPN5SV3646-3
Active

Siemens SENTRON RCCB, 4-pole, Type F, short-time delayed, 63 A rated current, 300 mA residual current, 10 kA SCCR, 400 V AC, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SV3646-3 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SV3646-3 — Identification
ParameterValue
Product designationRCCB
Product design / constructionShort-time delayed
5SV3646-3 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3646-3 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SV3646-3 is a 4-pole residual current circuit breaker (RCCB) from the SENTRON family, Type F, short-time delayed, rated 63 A with a 300 mA residual operating current for 400 V AC systems at 50/60 Hz. The short-time delay (Type F) means it tolerates brief high-frequency leakage pulses from variable-speed drives or UPS equipment without nuisance tripping — a common need on modern lines with VFD-fed motors.

Snaps onto DIN rail (REG) — standard 35 mm profile. Depth is 70 mm, same as the installation depth, so it sits flush with the front edge of a standard distribution board. The IP20 rating applies once the distribution board is installed with conductors connected; that's typical for enclosed panel gear, not for open-chassis use.

The 300 mA residual sensitivity is a higher threshold than the standard 30 mA, chosen for equipment protection or where leakage from drives would trip a more sensitive unit. The short-time delay (Type F per IEC 61008-1) gives it a 0.8 kA rated conditional short-circuit current according to that standard, and the 10 kA SCCR covers the fault-clearing capability per IEC 60947-2.

Frequently asked questions

Where can I buy the 5SV3646-3?

This RCCB is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit a request and we'll get you a firm line.

What is the difference between the 5SV3646-3 and a standard 30 mA RCCB?

The 5SV3646-3 is a Type F short-time delayed RCCB with 300 mA residual sensitivity, designed to ride through leakage from VFDs and UPS systems without tripping. A standard 30 mA RCCB would nuisance-trip on those waveforms. The 300 mA threshold also suits equipment protection rather than personnel shock protection.

Does the 5SV3646-3 fit in a panel designed for a 5SL4363-7 MCB?

No — the 5SV3646-3 is 4-pole, 72 mm wide (4 MW), while the 5SL4363-7 is a 3-pole MCB at 54 mm (3 MW). The depth is similar (70 mm vs 76 mm), but the width and pole count differ. You'd need to re-space the DIN rail and re-feed the neutral through the fourth pole.