Siemens 5SV3646-8KL — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV3646-8KL RCCB, 4-Pole, 63 A, 300 mA Type A

MPN5SV3646-8KL
Active

Siemens SENTRON 5SV3646-8KL, 4-pole RCCB, 63 A rated current, 300 mA Type A residual current, selective design, DIN rail mount.

$221.13Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV3646-8KL — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SV3646-8KL — Identification
ParameterValue
Product designationRCCB
Product design / constructionSelective
5SV3646-8KL — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3646-8KL — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

Panel fit and selectivity

The Siemens 5SV3646-8KL is a 4-pole SENTRON RCCB rated 63 A at 40 °C through 55 °C, with a 300 mA Type A residual current trip and a selective (time-delayed) characteristic. The selective design means it withstands a 5 kA surge current without tripping, coordinating downstream with standard RCCBs so only the faulted branch clears. This avoids nuisance blackouts on the main incomer when a downstream device sees a transient earth fault.

At 65 °C it derates to 57.35 A, and at 70 °C to 48.8 A. The maximum permissible ambient for storage is 75 °C, with a minimum of -40 °C. Operating frequency is 50/60 Hz, and the supply frequency is rated at 50 Hz. The short-circuit current rating is 10 kA per IEC 61008-1, with an I²t withstand of 110 000 A²·s and a let-through current of 7 100 kA.

The part is silicon-free, which matters for paint-shop or potting applications where silicone outgassing causes adhesion failure.

Installation and approvals

Mounts on DIN rail (REG) in any position. Overvoltage category III, IP20 protection (with connected conductors in an installed distribution board). The test button requires a minimum 100 V supply. Approvals include EN 60898 (rated 0.8 kA) and IEC 61008-1 (rated 0.8 kA). The Type A residual current detection handles AC sinusoidal and pulsating DC fault currents — the standard choice for circuits with rectified loads like switching power supplies or variable-speed drives.

Frequently asked questions

Can a 4-pole RCCB be used in a single-phase system?

Yes, a 4-pole RCCB like the 5SV3646-8KL can be used in a single-phase system by connecting the phase and neutral through two of the poles and leaving the remaining two poles unused. The device monitors the vector sum of currents through all connected poles.