Siemens 5SV3646-8LA — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV3646-8LA SENTRON RCCB, 4P, 63A, 300mA Type A, Sel

MPN5SV3646-8LA
Active

Siemens SENTRON RCCB, 5SV3646-8LA, 4-pole, 63 A rated current, 300 mA Type A selective residual current circuit breaker, DIN rail mount, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SV3646-8LA — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SV3646-8LA — Identification
ParameterValue
Product designationRCCB
Product design / constructionSelective
5SV3646-8LA — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3646-8LA — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SV3646-8LA is a SENTRON-series RCCB (residual current circuit breaker) designed for 4-pole, 63 A circuits with a 300 mA Type A selective trip characteristic. The 300 mA rating means it's intended for general fault protection where a higher threshold is acceptable — typically on feeder circuits or sub-distribution boards — and the selective (time-delayed) design coordinates with downstream 30 mA RCCBs so only the faulted branch trips, not the whole board. Type A detection covers sinusoidal AC and pulsating DC residual currents up to 6 mA smooth DC, which covers most modern electronic loads like VFDs, switched-mode PSUs, and single-phase rectifiers. The 5SV3646-8LA carries a 10 kA short-circuit current rating (SCCR) per IEC 61008-1, with a conditional rating of 0.8 kA under EN 60898. The I²t let-through is rated at 110,000 A²·s, which governs the energy the device passes during a fault — relevant for coordination studies. Thermal performance is flat-rated at 63 A from 40 °C through 60 °C ambient, then derates to 57.35 A at 65 °C and 48.8 A at 70 °C. This means in a warm panel (say 55 °C), the device still carries its full 63 A without derating — a useful margin for tightly packed enclosures.

Installation depth matches the body depth at 70 mm.

Frequently asked questions

What is the difference between the 5SV3646-8LA and a standard Type AC RCCB?

The 5SV3646-8LA is a Type A RCCB, which detects both sinusoidal AC and pulsating DC residual currents up to 6 mA smooth DC. A standard Type AC RCCB only detects sinusoidal AC. For panels with VFDs, switched-mode PSUs, or other electronic loads that generate pulsating DC faults, Type A is the correct choice.

What does the 'selective' design mean on this RCCB?

The selective (time-delayed) design means the 5SV3646-8LA will not trip on short-duration earth faults that are cleared by downstream 30 mA RCCBs. This ensures only the faulted branch is isolated, keeping the main distribution board live — critical for process continuity in industrial panels.

How do I get current pricing and availability for 5SV3646-8LA?

Pricing and availability are confirmed at quote time against an RFQ through independent distribution. Submit an RFQ with your target quantity and delivery window for a current commercial offer.