Siemens 5SV3744-4 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV3744-4 SENTRON RCCB, Type B, 40 A, 4-Pole, 10 kA

MPN5SV3744-4
Active

Siemens SENTRON RCCB, 5SV3744-4, 4-pole, Type B, 40 A rated, 500 mA residual trip, 10 kA SCCR, short-time delayed, DIN rail mount, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SV3744-4 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SV3744-4 — Identification
ParameterValue
Product designationRCCB
Product design / constructionShort-time delayed
5SV3744-4 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3744-4 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SV3744-4 is a SENTRON RCCB — a residual-current circuit breaker — in a 4-pole, Type B, short-time delayed design. It's rated 40 A continuous at 40 °C, trips on a 500 mA residual fault, and can clear a 10 kA short-circuit fault. The Type B classification means it detects smooth DC residual currents plus the usual AC and pulsed DC, so it's the right device for drives, UPS systems, or any load with rectifiers or frequency converters that dump DC fault current back onto the line. The short-time delayed characteristic (K-type or S-type in some families) prevents nuisance tripping from transient surge currents up to 3 kA.

Snaps onto standard DIN rail (REG profile). Mounting position is unrestricted, which helps when you're wedging it into a tight corner of an existing panel. IP20 with conductors connected, so it's for use inside a distribution board enclosure, not out in the washdown zone.

Thermal performance

That's unusual for a thermal-magnetic device; it means the bimetal or electronic trip element is compensated for ambient temperature rise inside a warm panel.

Frequently asked questions

What does Type B residual current mean on this RCCB?

Type B detects smooth DC residual currents, AC sinusoidal, and pulsed DC — required for equipment with three-phase rectifiers, variable-frequency drives, or UPS systems where a Type A or AC device would miss a DC fault.

What is the short-circuit current rating (SCCR) of the 5SV3744-4?

10 kA, which is the standard SCCR for a DIN-rail RCCB in a residential or light-commercial panel. It also carries an 0.8 kA rating per EN 60898 and IEC 61008-1 for the residual-current function.

Will the 5SV3744-4 drop into a panel built for a 5SL4363-7?

Not without rewiring. The 5SL4363-7 is a 3-pole MCB; the 5SV3744-4 is a 4-pole RCCB. Same DIN-rail footprint, but the function and connections are different — the RCCB needs the neutral conductor through it, and it occupies 4 width units instead of 3.

Where can I buy the 5SV3744-4?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SV3744-4