Skip to main content
Siemens 5SV3746-4 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV3746-4 SENTRON RCCB, Type B, 63 A, 4-Pole, 500 mA

MPN5SV3746-4
Active

Siemens SENTRON RCCB, Type B, 4-pole, 63 A, 500 mA trip, short-time delayed, 10 kA SCCR, DIN rail mount, 4 MW, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SV3746-4 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SV3746-4 — Identification
ParameterValue
Product designationRCCB
Product design / constructionShort-time delayed
5SV3746-4 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3746-4 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SV3746-4 is a SENTRON residual current circuit breaker (RCCB) — a 4-pole, Type B device rated for 63 A continuous at 40 °C through 55 °C, with a 500 mA residual trip threshold. Type B means it detects AC, pulsating DC, smooth DC, and high-frequency residual currents, so it covers VFD-fed motor circuits, UPS feeds, and EV charging infrastructure where pure AC-sensing RCCBs would miss DC fault components. The short-time delayed design (SIGRES function) lets it ride through transient earth faults without nuisance tripping, which matters on circuits with surge arrestors or capacitive filters that dump a brief ground current on power-up.

The supply can enter top or bottom; the SIGRES function stays powered even when switched off if fed from the top. IP20 with conductors connected, so it lives inside a distribution board, not exposed to washdown.

Thermal derating and fault handling

At 65 °C it derates to 55 A; at 70 °C it drops to 48 A. Short-circuit withstand is 10 kA per IEC 61008-1, with a let-through current limit of 7 000 A and an I²t of 60 000 A²·s. Surge current resistance is 3 kA; the impulse withstand per the standard is 0.8 kA. Overvoltage category III — suitable for fixed-installation distribution panels.

Frequently asked questions

What is the difference between 5SV3746-4 and a standard AC-type RCCB?

The 5SV3746-4 is Type B, meaning it detects AC, pulsating DC, smooth DC, and high-frequency residuals. A standard AC-type RCCB only sees sinusoidal AC leakage. For circuits with VFDs, UPS, or EV chargers, Type B is the correct choice — an AC-type will miss DC fault components and may not trip.

What is the 5SV3746-4's rated residual tripping current?

500 mA. That is a higher threshold than the common 30 mA or 100 mA RCCBs — it is intended for equipment protection (fire prevention on distribution circuits) rather than direct personal shock protection.

Where can I buy 5SV3746-4 and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Does 5SV3746-4 drop into a panel designed for a standard 4-pole RCCB?

Yes. It occupies 4 modular width units (72 mm) on standard DIN rail, same footprint as any 4-pole 63 A RCCB. The supply can enter top or bottom. No special panel modifications needed.

MPN
5SV3746-4