Siemens 5SV3746-5 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV3746-5 SENTRON RCCB, Type B selective, 63A 500mA

MPN5SV3746-5
Active

Siemens SENTRON 5SV3746-5, 4-pole Type B selective RCCB, 63 A rated current, 500 mA rated residual current, Un AC 400 V, DIN rail mount, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SV3746-5 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SV3746-5 — Identification
ParameterValue
Product designationRCCB
Product design / constructionSelective
5SV3746-5 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV3746-5 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SV3746-5 is a 4-pole Type B selective residual current circuit breaker (RCCB) from the SENTRON family, rated 63 A and 500 mA residual sensitivity on a 400 V AC supply. The selective design means it incorporates a short-time delay so that, in a fault, the downstream RCCB trips first — only if the fault persists does this unit clear, keeping upstream circuits live. That discrimination is essential in a multi-level distribution board where you want the nearest device to the fault to open, not the main incomer.

Type B detection covers AC, pulsating DC, and smooth DC residual currents up to 500 mA — the right choice for drives, UPS systems, and other loads that can generate DC fault currents a standard Type A RCCB would not see. Mounting position is unrestricted.

Type B selective RCCBs are specified in commercial and industrial distribution boards where the supply feeds equipment that can produce smooth DC fault currents — variable-frequency drives, UPS systems, EV chargers, and medical imaging equipment. The selective time delay avoids nuisance tripping from transient earth faults and coordinates with downstream RCCBs so only the faulted branch opens. The 63 A rating covers sub-distribution or feeder circuits in a 400 V TN or TT system.

Frequently asked questions

Where can I buy the 5SV3746-5 and get a price?

The 5SV3746-5 is sourced and quoted to order through independent distribution. Submit an RFQ; availability and current pricing are confirmed at quote time — no stock count or price figure is carried on this listing.

What does Type B selective mean on this RCCB?

Type B detects AC, pulsating DC, and smooth DC residual currents — necessary where VFDs or UPS units are present. Selective means it has a short intentional delay so it coordinates with downstream RCCBs: the downstream device clears first, and only a persistent fault opens this unit, preserving supply to other circuits.

What is the depth of the 5SV3746-5?

The depth is 70 mm, with an installation depth also listed as 70 mm — it fits standard SENTRON distribution boards and enclosures with that internal clearance.

MPN
5SV3746-5