Specifications

5SV4342-0KL — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SV4342-0KL — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SV4342-0KL — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV4342-0KL — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The 5SV4342-0KL: Mounts on standard DIN rail (REG) in any orientation. The 72 mm width (4 modular units) fits standard panel cutouts. IP20 protection applies once the distribution board is installed and conductors connected — not rated for open-panel exposure to dust or moisture. Silicon-free construction suits environments where outgassing must be avoided (e.g., adjacent to sensitive contacts or coatings).

Thermal Derating & Ambient Limits

Rated 25 A continuously from 40 °C up to 60 °C ambient. At 65 °C it derates to 23.3 A; at 70 °C to 17.6 A. The I²t withstand of 58 000 A²·s gives the let-through energy the device can survive under fault conditions.

Installation & Wiring Notes

The installation depth is 70 mm — verify enclosure internal depth before panel layout. Overvoltage category III (distribution-board level). The 0.8 kA rated conditional short-circuit current per EN 60898 and IEC 61008-1 applies when backed by an upstream overcurrent device of that rating. For testing equipment, minimum supply voltage is 195 V.

Frequently asked questions

Will 5SV4342-0KL drop into a panel specified around 5SJ6325-7RC without rewiring?

Both are 4-pole RCCBs in the SENTRON family with DIN-rail mounting and 72 mm width (4 MW), so the mechanical footprint matches. However, 5SV4342-0KL is a Type AC (sinusoidal AC residual only) while the 5SJ6325-7RC is a different variant — verify the residual-current type and rating against your original specification before substituting.

How do I get current pricing and availability for 5SV4342-0KL?

Pricing and availability are confirmed at quote time against an RFQ through independent distribution channels — submit a request for the most current figures.