Siemens 5SV4416-0KL — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV4416-0KL SENTRON RCCB, 63 A, 100 mA, 2-pole, AC t

MPN5SV4416-0KL
Active

Siemens SENTRON 5SV4 series RCCB, 2-pole, AC type, 63 A rated current, 100 mA residual tripping, 10 kA short-circuit current rating, 230/400 V AC, DIN rail mount, 70 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SV4416-0KL — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV4416-0KL — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SV4416-0KL — Mechanical
ParameterValue
Mounting positionany
Width36 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV4416-0KL — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SV4416-0KL is a 2-pole residual current circuit breaker (RCCB) from the SENTRON 5SV4 series, designed for AC fault currents. It carries a rated current of 63 A at ambient temperatures up to 60 °C without derating, and a 100 mA residual tripping threshold — a common choice for general-purpose shock protection in distribution boards where a higher trip level is acceptable to avoid nuisance tripping on leakage from filters or long cable runs. Rated 230/400 V AC, 10 kA SCCR. DIN rail mount, 2 width units (36 mm wide), 70 mm depth.

Thermal performance and conductor sizing

This RCCB holds its full 63 A rating from 40 °C through 60 °C ambient — no derating curve to track in most panel environments. At 65 °C it drops to 56.96 A, and at 70 °C to 48.19 A. For a panel running hot near the upper operating limit of -25 to +45 °C, the 63 A rating is fully available. Terminals accept 0.75 mm² to 35 mm² solid or stranded. I²t rating 110,000 A²s.

Mounting and installation notes

DIN rail (REG) mounting, any position allowed — no orientation restriction. The N-left product variation means the neutral pole is on the left side when viewed from the front, matching the standard SENTRON busbar layout for 2-pole RCCBs. IP20 when installed in distribution board with conductors connected. Finger and back-of-hand safe.

Frequently asked questions

What conductor sizes does the 5SV4416-0KL accept?

Solid and stranded conductors from 0.75 mm² up to 35 mm². That covers typical distribution wiring from lighting circuits to main feeds.

MPN