Skip to main content
Siemens 5SV4442-0 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV4442-0 SENTRON RCCB, 4P, 25A, 100mA, 400V AC

MPN5SV4442-0
Active

Siemens SENTRON 5SV4442-0 RCCB, 4-pole, Type AC, In: 25 A, 100 mA, Un AC: 400 V, DIN rail mount, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SV4442-0 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SV4442-0 — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SV4442-0 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV4442-0 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens SENTRON 5SV4442-0 is a 4-pole residual current operated circuit breaker (RCCB), Type AC, rated 25 A with a 100 mA trip sensitivity at 400 V AC.

That makes it suitable for circuits without rectified loads, VFDs, or UPS systems where DC leakage is present. For mixed loads, a Type A or Type B RCCB would be needed. The 25 A rating and 400 V AC supply voltage (230/400 V range) suit it for three-phase sub-distribution or feeder circuits in commercial or light industrial panels. The short-circuit current rating (SCCR) is 10 kA per IEC 61008-1, with a maximum permissible series fuse of 80 A. In a panel, coordinate the upstream breaker to ensure the SCCR of the assembly is met. Rated for overvoltage category III, it is designed for fixed installation in the distribution board, not for plug-in or portable use.

Snap-on DIN rail (REG) mounting, any position. Depth is 70 mm, matching the standard installation depth for SENTRON modular devices. The 72 mm width (4 MW) means it occupies four 18 mm slots on the rail. Supply can be connected from top or bottom. Supplementary devices (like auxiliary switches or shunt trips) can be installed on the side — check the product extension options for compatibility.

Frequently asked questions

What is the 5SV4442-0 used for?

It is a 4-pole residual current circuit breaker (RCCB) for AC residual current protection in three-phase distribution boards, rated 25 A, 100 mA sensitivity at 400 V AC. It protects against earth faults in circuits without DC components.

What are the key ratings of the 5SV4442-0?

4-pole Type AC RCCB, 25 A rated current, 100 mA residual sensitivity, 400 V AC supply voltage, 10 kA SCCR per IEC 61008-1, 50 Hz operating frequency, and a mechanical life of 10,000 cycles.

Where can I buy the 5SV4442-0?

This part is sourced and quoted to order against an RFQ through independent industrial distribution. Availability and current pricing are confirmed at quote time.

Does the 5SV4442-0 fit in a standard DIN rail panel?

Yes. It snaps onto a DIN rail (REG), occupies 4 modular width units (72 mm), and has a 70 mm installation depth, matching standard SENTRON modular device spacing.

What compliance documentation is available for the 5SV4442-0?

The device carries an IP20 protection class (when installed in a distribution board with conductors connected) and is rated for overvoltage category III. It is designed to IEC 61008-1. Specific RoHS/REACH/UL documentation should be confirmed at time of order.