Skip to main content
Siemens 5SV4444-0LA01 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV4444-0LA01 SENTRON RCCB, 4-pole, 40 A, 100 mA, Ty

MPN5SV4444-0LA01
Active

Siemens SENTRON 5SV4444-0LA01 RCCB, 4-pole, Type AC, short-time delayed, In: 40 A, 100 mA, Un AC: 400 V, with thermal overload protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SV4444-0LA01 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SV4444-0LA01 — Identification
ParameterValue
Product designationRCCB
Product design / constructionShort-time delayed
5SV4444-0LA01 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV4444-0LA01 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

It snaps onto a DIN rail (REG) and fits a 60 mm grid spacing, occupying 4 modular width units.

The top or bottom supply feed gives flexibility in panel layout. IP20 rating applies once the distribution board is installed with conductors connected — standard for enclosed panel gear. The short-time delay feature (switching function short-term delayed) prevents nuisance tripping from transient leakage currents, which is useful on circuits with motor drives or switching power supplies that generate brief inrush leakage.

The 230/400 V AC supply voltage at 50/60 Hz covers standard European and many international panel voltages. Silicon-free construction is noted for environments sensitive to silicone outgassing.

Frequently asked questions

Where can I buy 5SV4444-0LA01?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings of 5SV4444-0LA01?

It is a 4-pole RCCB, Type AC, rated 40 A with 100 mA sensitivity, short-time delayed, 10 kA SCCR per IEC 61008-1, and includes thermal overload protection. Supply voltage is 230/400 V AC at 50/60 Hz.

What is the difference between 5SV4444-0LA01 and 5SL4363-7?

The 5SL4363-7 is a 3-pole miniature circuit breaker (MCB) with C-curve trip characteristic, not an RCCB. It lacks residual current detection and thermal overload protection. The 5SV4444-0LA01 is a 4-pole RCCB with 40 A rating and 100 mA leakage trip. They serve different protection functions — MCB for overcurrent, RCCB for ground fault — and are not drop-in replacements for each other.

MPN
5SV4444-0LA01