Siemens 5SV5312-0FC — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV5312-0FC SENTRON RCCB, 25A, 30mA, 2-Pole, Type AC

MPN5SV5312-0FC

Siemens SENTRON 5SV5312-0FC, 2-pole RCCB, Type AC, 25 A rated, 30 mA trip, 230 V AC, 6 kA SCCR, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV5312-0FC — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV5312-0FC — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SV5312-0FC — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum45 °C
Minimum-25 °C
Width36 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV5312-0FC — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

Siemens 5SV5312-0FC SENTRON RCCB — 25 A, 30 mA, Type AC

The Siemens 5SV5312-0FC is a 2-pole residual current operated circuit breaker (RCCB) from the SENTRON series, rated 25 A with a 30 mA trip threshold, Type AC, instantaneous design, for 230 V AC at 50 Hz. Its short-circuit current rating (SCCR) is 6 kA per the device's own rating, with an additional conditional rating of 0.5 kA according to EN 60898 and IEC 61008-1 — the 6 kA figure governs the upstream protective device coordination.

Mounting position is unrestricted — horizontal, vertical, or flat. Depth is 70 mm, matching standard distribution board cutouts. The test button requires a minimum of 195 V to operate correctly.

Rated operational voltage is 230 V AC, 50 Hz. Overvoltage category III (fixed installation). The device is instantaneous (no short-time delay), so it trips without intentional delay on a residual fault. Permissible let-through energy (I²t) is 58,000 A²·s, and the let-through current rating is 5,200 kA — these values define the thermal and magnetic stress the RCCB can withstand during a fault before the upstream breaker clears. Ambient operating range: -25 °C to +45 °C. Mechanical service life is 2,000 switching cycles typical. Silicon-free construction. Fits DIN 43880 size 1 enclosures.

Frequently asked questions

What is the 5SV5312-0FC used for?

It is a 2-pole residual current circuit breaker (RCCB) for personnel protection in 230 V AC circuits, tripping at 30 mA sinusoidal residual current. Typical use is in residential or commercial distribution boards where only AC fault currents are expected.

What are the key ratings of the 5SV5312-0FC?

Rated current 25 A, trip sensitivity 30 mA, Type AC, 2-pole, 230 V AC, 50 Hz, SCCR 6 kA, instantaneous trip, DIN rail mount, 2 MW (36 mm wide).

Where can I buy the 5SV5312-0FC?

The 5SV5312-0FC is available to order against an RFQ through independent distribution. Pricing and current availability are confirmed at quote time.

Will the 5SV5312-0FC drop into a panel specified for the 5SU9354-7KK16?

Both are 2-pole SENTRON devices on DIN rail, 36 mm wide, 70 mm installation depth. The 5SV5312-0FC is a pure RCCB (no overcurrent protection), while the 5SU9354-7KK16 is an RCBO (RCD + MCB in one unit). The panel cutout and busbar arrangement are the same, but the circuit protection function differs — the 5SV5312-0FC requires a separate upstream MCB for overcurrent protection.