Skip to main content
Siemens 5SV5314-0 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SV5314-0 RCCB, 2-pole Type AC, 40 A 30 mA

MPN5SV5314-0
Active

Siemens SENTRON RCCB, 2-pole, Type AC, In: 40 A, 30 mA, Un AC: 230 V, 6 kA SCCR, DIN rail mount, 2 MW.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV5314-0 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV5314-0 — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SV5314-0 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum45 °C
Minimum-25 °C
Width36 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV5314-0 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens SENTRON 5SV5314-0 is a 2-pole Type AC residual current circuit breaker (RCCB) rated 40 A with 30 mA trip sensitivity, designed for 230 V AC 50 Hz systems.

In a panel with a 6 kA prospective fault current at the bus, this device coordinates — no need for a current-limiting upstream breaker unless the fault level exceeds that figure. The 30 mA residual sensitivity is the standard threshold for personnel protection in most national wiring rules (IEC 60364, UK BS 7671, etc.). The IP20 rating applies only when the distribution board is installed and conductors are connected; outside the enclosure the terminals are not touch-safe, so it must live inside a locked or tool-accessible panel.

Panel integration

Silicon-free construction is confirmed — relevant for potting or conformal-coating processes where silicone contamination must be avoided.

Frequently asked questions

Where can I buy the 5SV5314-0 and get a price?

The 5SV5314-0 is sourced to order through independent distribution. Submit an RFQ; we confirm availability and current pricing at quote time. No stock count or price is published here because market conditions change daily.

What is the 5SV5314-0's depth?

The listed depth is 70 mm (installation depth also 70 mm). That fits standard 60 mm grid-spacing DIN-rail enclosures with clearance for wiring behind the rail.

Will the 5SV5314-0 drop into a panel specified around the 5SY7210-7CC without rewiring?

Both are 2-pole, 36 mm wide (2 MW), DIN-rail mounted SENTRON devices with the same 70 mm installation depth. The 5SV5314-0 is an RCCB (residual current protection); the 5SY7210-7CC is an MCB (overcurrent protection). They serve different functions — you cannot swap one for the other without changing the circuit protection scheme. Physically they occupy the same footprint, but the wiring and protection coordination must be redesigned.

MPN
5SV5314-0