Siemens 5SV5314-0FB — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV5314-0FB SENTRON RCCB, 2-pole, 40 A, 30 mA, Type

MPN5SV5314-0FB

Siemens SENTRON 5SV5314-0FB, 2-pole RCCB, Type AC, 40 A rated, 30 mA trip sensitivity, 230 V AC, 50 Hz, 6 kA short-circuit current rating, DIN rail mount, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV5314-0FB — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV5314-0FB — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SV5314-0FB — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum45 °C
Minimum-25 °C
Width36 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV5314-0FB — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SV5314-0FB is a SENTRON residual current circuit breaker (RCCB), 2-pole, Type AC, rated 40 A with 30 mA trip sensitivity on a 230 V AC, 50 Hz supply. The short-circuit current rating (SCCR) is 6 kA per IEC 61008-1, and the permissible let-through current is 5,200 A with an I²t value of 58,000 A²·s.

The 70 mm depth matches the standard SENTRON RCCB/MCB footprint, so it aligns with busbars and adjacent devices in a Siemens distribution board without extra spacing. Rated IP20 with conductors connected and the distribution board installed — that's touch-safe but not washdown-rated. Keep it inside a closed enclosure; it's not meant for outdoor or wet-area exposure.

If your panel runs hotter, you'll need to derate per the thermal curve — but at standard 30 °C ambient it handles the full 40 A without issue. The 30 mA trip threshold is the standard for personnel protection (GFCI class); for equipment protection you'd typically go higher, but this is the right pick for socket-outlet circuits in residential or light commercial. Overvoltage Category III means it's rated for fixed-installation distribution panels (not for sensitive electronics). The silicon-free construction (yes) is a plus for environments where silicone outgassing can contaminate contacts or optics — a detail that matters in automotive paint shops or cleanroom-adjacent panels.

Frequently asked questions

Will the 5SV5314-0FB drop into a panel specified around the 5SL6550-7BB?

The 5SV5314-0FB shares the same 36 mm width (2 MW), 90 mm height, and DIN-rail mounting as the 5SL6550-7BB, so the physical footprint is identical. However, the 5SV is an RCCB and the 5SL is an MCB — they serve different protection functions. You can mechanically swap them in the same DIN slot, but the wiring and protection scheme must match the device type.