Skip to main content
Siemens 5SV5344-0MB — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SV5344-0MB RCCB, 4-pole, 40 A, 30 mA

MPN5SV5344-0MB

Siemens SENTRON RCCB, 4-pole, Type AC, In: 40 A, 30 mA, Un AC: 400 V, 60 Hz, DIN rail mount, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV5344-0MB — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SV5344-0MB — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SV5344-0MB — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV5344-0MB — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

It's built for 400 V AC, 60 Hz systems and snaps onto a standard DIN rail — 4 modular width units (72 mm wide) with a 70 mm installation depth. The IP20 rating means it's meant for enclosed distribution boards, not open washdown areas.

The 70 mm depth and 72 mm width (4 MW) are standard for a 4-pole RCCB in this class — it'll fit a typical 60 mm grid-spaced enclosure without surprises. Feed from top or bottom; no special orientation required.

Frequently asked questions

What is the 5SV5344-0MB used for?

It's a residual current circuit breaker (RCCB) for protecting circuits against earth faults. The 30 mA trip sensitivity covers personnel protection, and the 40 A rating suits feeder or submain circuits in commercial or industrial distribution boards.

What are the key ratings of the 5SV5344-0MB?

Rated at 40 A, 30 mA residual current, Type AC (sinusoidal AC fault detection only), 400 V AC, 60 Hz. Short-circuit withstand is 6 kA per IEC 61008-1. Operating temperature range is -25 °C to +45 °C.

Where can I buy the 5SV5344-0MB?

Sourced and quoted to order against an RFQ through our independent distribution channel. Availability and current pricing are confirmed at quote time — no stock figures or lead-time numbers are published here.

Will the 5SV5344-0MB drop into a panel specified around a 5SJ6325-7RC?

No — the 5SJ6325-7RC is a 3-pole miniature circuit breaker (MCB), not an RCCB. The 5SV5344-0MB is a 4-pole residual current device. They serve different protection functions and have different footprints (4 MW vs 3 MW). A panel designed for an MCB won't accept an RCCB without rewiring and re-spacing.

MPN
5SV5344-0MB