Skip to main content
Siemens 5SV5616-0 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV5616-0 SENTRON RCCB, 2-pole, 63 A, 300 mA, Type A

MPN5SV5616-0
Active

Siemens SENTRON 5SV5616-0, 2-pole RCCB, Type AC, 63 A rated, 300 mA residual, 6 kA SCCR, 2 MW, DIN rail mount, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV5616-0 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV5616-0 — Identification
ParameterValue
Product designationRCCB
Product design / constructionInstantaneous
5SV5616-0 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum45 °C
Minimum-25 °C
Width36 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SV5616-0 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SV5616-0 is a 2-pole residual current operated circuit breaker (RCCB) from the SENTRON family, rated 63 A at 230 V AC with a 300 mA residual trip threshold, Type AC (sinusoidal AC fault currents only). It is an instantaneous-trip device (no intentional short-time delay), so it clears ground faults within one cycle — the right choice for general-purpose socket circuits and lighting where nuisance tripping from transient surges is not a concern. The 6 kA short-circuit current rating (SCCR) per EN 60898 and IEC 61008-1 means the device safely interrupts a fault up to that level without rupturing — adequate for most residential and light commercial distribution boards where the prospective fault current stays under 6 kA.

Rated 63 A at 40 °C ambient, with a permissible I²t of 110 000 A²·s for through-fault energy let-through — useful for coordinating with downstream MCBs and ensuring the RCCB withstands the thermal stress of a bolted fault before the upstream device clears. Operating temperature range is -25 °C to +45 °C; storage range extends from -40 °C to +75 °C, so the device can be warehoused in unconditioned spaces but must be commissioned within the narrower operating band. Overvoltage category III — suitable for fixed-installation distribution boards where transient overvoltages from the utility side are expected.

Silicon-free construction matters for automotive paint-shop or semiconductor-fab installations where silicone outgassing can contaminate surfaces; the 5SV5616-0 carries that designation.

Frequently asked questions

What is the 5SV5616-0 used for?

It is a 2-pole residual current circuit breaker (RCCB) for 230 V AC circuits, rated 63 A with a 300 mA residual trip threshold, Type AC (sinusoidal AC faults). It provides ground-fault protection in residential and light commercial distribution boards.

MPN
5SV5616-0