Skip to main content
Siemens 5SV6016-6KK25 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV6016-6KK25 SENTRON AFDD+MCB, 25 A, B-curve, 6 kA

MPN5SV6016-6KK25
Active

Siemens SENTRON AFDD-MCB combination, 230 V AC, 25 A, B-curve, 6 kA, 1P+N, compact 1 MW unit, halogen-free, silicon-free.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV6016-6KK25 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV6016-6KK25 — Identification
ParameterValue
Product design / constructionCompact unit
5SV6016-6KK25 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth68.5 mm
Installation depth70 mm
5SV6016-6KK25 — Environmental
ParameterValue
IP degree of protectionIP20, with connected protective device and conductors
5SV6016-6KK25 — Electrical
ParameterValue
Tripping Characteristic ClassB
Operational current / at AC / rated value25 A

Product details

Arc-fault detection device with integrated MCB

The Siemens SENTRON 5SV6016-6KK25 is an AFDD combined with an MCB in one compact unit — 18 mm wide on DIN rail. It protects a 230 V AC, 50 Hz circuit against arcing faults and provides overcurrent and short-circuit protection via the B-curve MCB section.

The B-curve tripping characteristic means the magnetic trip fires at 3 to 5 times rated current — 75 to 125 A for this 25 A unit. The arc-fault detection covers series arcs (up to 25 A, minimum 2 A) and parallel arcs (up to 500 A, minimum 50 A) (–), meaning it can detect a loose connection or a carbonised cable before the fault escalates to a fire. The 10 000 mechanical switching cycles reflect a service life consistent with a main distribution or sub-main position that sees occasional manual switching, not daily load-break duty.

Snaps onto DIN rail (REG) and occupies one modular width unit (18 mm). The 68.5 mm depth plus 70 mm installation depth means it fits standard distribution boards with 70 mm deep enclosures.

Frequently asked questions

Will 5SV6016-6KK25 drop into a panel that was specified around 5SL3116-6MB without rewiring?

The 5SV6016-6KK25 shares the same 18 mm width and DIN-rail mounting as the 5SL3116-6MB, so it fits the same panel footprint. However, the 5SL3116-6MB is a standalone MCB without arc-fault detection, while the 5SV6016-6KK25 is an AFDD+MCB combination with a neutral-switching 1P+N design — the wiring differs because the AFDD requires a neutral connection for arc-fault sensing. A direct drop-in without rewiring is not possible.

MPN
5SV6016-6KK25