Skip to main content
Siemens 5SV6016-6KK40 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV6016-6KK40 SENTRON AFDD+MCB, 40A, B-curve, 6kA

MPN5SV6016-6KK40
Active

Siemens SENTRON AFDD-MCB combination, order code 5SV6016-6KK40, 230 V AC, 40 A, B-curve, 6 kA breaking capacity, 1P+N, 18 mm wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV6016-6KK40 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV6016-6KK40 — Identification
ParameterValue
Product design / constructionCompact unit
5SV6016-6KK40 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth68.5 mm
Installation depth70 mm
5SV6016-6KK40 — Environmental
ParameterValue
IP degree of protectionIP20, with connected protective device and conductors
5SV6016-6KK40 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

It protects a final circuit against arc faults (series and parallel arcs) and provides overcurrent and short-circuit protection in a single DIN-rail module.

Rated at 40 A, 230 V AC, this unit handles a standard single-phase final circuit up to that current. The breaking capacity of 6 kA per EN 60898-1 and IEC 60947-2 means it can safely interrupt a fault current of up to 6,000 A — adequate for most residential and light commercial installations where the prospective short-circuit current at the panel is under that threshold. The 1P+N design switches the line conductor and switches the neutral, offering disconnection of both poles in a single-width module. At 18 mm wide and 68.5 mm deep, it occupies one modular-width slot on the DIN rail, leaving room for adjacent devices.

The compact unit design allows installation of supplementary devices such as auxiliary switches or shunt trips if needed later.

Frequently asked questions

Where can I buy 5SV6016-6KK40 and how do I get a price?

The 5SV6016-6KK40 is available to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current availability and pricing.

What is the difference between 5SV6016-6KK40 and the 5SL3116-6MB?

The 5SV6016-6KK40 is an AFDD-MCB combination (arc-fault detection plus overcurrent protection), while the 5SL3116-6MB is a standard miniature circuit breaker only. The 5SV6016-6KK40 has a 40 A rating and B-curve; the 5SL3116-6MB is a 16 A, B-curve MCB. Both are 18 mm wide and snap onto DIN rail, but the AFDD adds arc-fault detection and switches the neutral (1P+N). The 5SL3116-6MB is a single-pole MCB and does not include arc-fault detection.

What compliance documentation does Siemens provide for 5SV6016-6KK40?

The product carries an IEC/EN 60898-1 and IEC 60947-2 rating. It is halogen-free and silicon-free. Standard compliance documentation (RoHS, REACH, CE) is provided with the product; specific declarations are available from Siemens upon request.

MPN