Siemens 5SV6016-6MC10 SENTRON AFDD-MCB, 6 kA, Class B, 2-Pol

MPN5SV6016-6MC10

Siemens SENTRON AFDD-MCB combination, 5SV6016-6MC10, 2-pole 1P+N, Class B, 6 kA (EN 60898-1), 230 V AC, integrated metering, DIN rail mount, 18 mm width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV6016-6MC10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV6016-6MC10 — Identification
ParameterValue
Product designationAFDD-MCB combination
Product design / constructionCompact unit
5SV6016-6MC10 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth68.5 mm
Installation depth70 mm
5SV6016-6MC10 — Environmental
ParameterValue
IP degree of protectionIP20, with connected protective device and conductors
5SV6016-6MC10 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

Arc-fault detection plus MCB in one module

The Siemens 5SV6016-6MC10 is a SENTRON AFDD-MCB combination unit — an arc-fault detection device (AFDD) and a miniature circuit breaker (MCB) integrated into a single compact housing. It occupies just 18 mm width (1 modular unit) on a DIN rail, with a depth of 68.5 mm and height of 90 mm. The 2-pole design uses a 1P+N configuration, switching the line and monitoring the neutral for arc faults. Integrated metering sets this apart: the unit includes an ammeter, voltmeter, wattmeter, frequency meter, and reactive power meter. Measurement accuracy is 0.5 % for current and voltage, 1 % for active power, compliant with IEC 61557-12, IEC 62053-22, and IEC 62053-23. The front-panel display cycles through voltage, current, active/reactive/apparent power, active energy, line frequency, power factor, temperature, switching cycles, operating hours, trip events, and warnings — giving a panel operator live circuit data without a separate meter.

If your installation has a higher fault level (e.g., near a transformer substation), you would need an MCB with a higher breaking capacity, typically 10 kA or 25 kA. The 18 mm width (1 modular unit) is the standard DIN-rail pitch for a single-pole MCB. This unit packs a 2-pole AFDD+MCB plus metering into that same 18 mm.

Frequently asked questions

What does the integrated metering measure on the 5SV6016-6MC10?

The unit measures voltage, current, active power, apparent power, reactive power, active energy, line frequency, power factor, temperature, switching cycles, operating hours, trip events, and warnings. Accuracy is 0.5 % for current and voltage, 1 % for active power.

What is the physical size of the 5SV6016-6MC10?

Width is 18 mm (1 modular unit), height is 90 mm, depth is 68.5 mm. Installation depth allowance is 70 mm. It snaps onto standard DIN rail (REG) and can be mounted in any position.

Is the 5SV6016-6MC10 suitable for railway applications?

Yes, it is rated for shock and vibration per IEC 61373, making it suitable for rolling stock and other transport applications. The wide temperature range (-40 °C to 75 °C) also supports unheated or outdoor enclosures.

MPN
5SV6016-6MC10