Siemens 5SV6016-6MC20 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV6016-6MC20 SENTRON AFDD-MCB, B-Curve 6kA, 1P+N

MPN5SV6016-6MC20

Siemens SENTRON 5SV6016-6MC20, AFDD-MCB combination unit, B-curve, 6 kA breaking capacity, 1P+N, 2-pole, integrated metering (A, V, W, Hz, VAR), DIN rail mount, IP20/IP40.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV6016-6MC20 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV6016-6MC20 — Identification
ParameterValue
Product designationAFDD-MCB combination
Product design / constructionCompact unit
5SV6016-6MC20 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth68.5 mm
Installation depth70 mm
5SV6016-6MC20 — Environmental
ParameterValue
IP degree of protectionIP20, with connected protective device and conductors
5SV6016-6MC20 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

Beyond the breaker function, it packs a full suite of metering: ammeter, voltmeter, wattmeter, frequency meter, and reactive power meter, all with seamless measurement detection. Accuracy runs 0.5 % for current and voltage, 1 % for active power, based on IEC 61557-12, IEC 62053-22, and IEC 62053-23. The status display cycles through voltage, current, active/apparent/reactive power, active energy, line frequency, power factor, temperature, switching cycles, operating hours, trip events, and warnings — all readable on the front face.

Snaps onto a DIN rail (REG fastening), any mounting position. Front face is IP40, rear side IP20 with connected protective device and conductors. Supports a wireless protocol for data communication, though the specific protocol isn't detailed in the base listing. The supply cord position is flexible (any), and the minimum test equipment voltage is 195 V.

Frequently asked questions

What compliance documentation does Siemens provide for 5SV6016-6MC20?

The unit is halogen-free and silicon-free. Accuracy standards are based on IEC 61557-12, IEC 62053-22, and IEC 62053-23. Shock qualification is per IEC 61373. Overvoltage category III, pollution degree 2.

Will 5SV6016-6MC20 drop into a panel specified around 5SL6120-7 without rewiring?

Both are 1-module-wide (18 mm) DIN-rail units, so the physical footprint is the same. But 5SV6016-6MC20 is an AFDD-MCB combination with integrated metering and wireless protocol support — it's a different class of device than a plain MCB. The wiring topology for arc-fault detection may differ; verify the circuit design before swapping.