Specifications

5SV6016-7KK06 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV6016-7KK06 — Identification
ParameterValue
Product designationAFDD-MCB combination
Product design / constructionCompact unit
5SV6016-7KK06 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth68.5 mm
Installation depth70 mm
5SV6016-7KK06 — Environmental
ParameterValue
IP degree of protectionIP20, with connected protective device and conductors
5SV6016-7KK06 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

Arc-fault detection in one module width

The Siemens 5SV6016-7KK06 is a SENTRON AFDD-MCB combination — an arc-fault detection device and miniature circuit breaker integrated into a single compact unit, rated 230 V AC at 50 Hz with a C-curve 6 A trip characteristic and 6 kA breaking capacity per both EN 60898-1 and IEC 60947-2. It occupies one modular width (18 mm) on a DIN rail, making it a space-efficient choice for final circuits where both overcurrent protection and series arc-fault detection are required in a single housing.

The 6 kA breaking capacity (Icn = 6 kA per EN 60898-1, Icu = 6 kA per IEC 60947-2) is the standard domestic and light-commercial interrupting rating — adequate for most final sub-distribution boards where the prospective short-circuit current at the point of installation does not exceed 6 kA. The 1P+N design switches the line conductor and provides neutral switching, which is required in some regional wiring regulations for arc-fault protection devices to ensure the arc is fully extinguished. The unit is halogen-free and silicon-free, a material constraint often specified for clean-room, aerospace, or semiconductor-adjacent installations where outgassing must be controlled. Power loss is 0.87 W per pole in hot operating state at rated current — negligible for thermal coordination in a populated enclosure, but worth noting when calculating cumulative heat rise in a sealed distribution board.

Deployment context

Snap-on DIN rail (REG) mounting, any orientation, IP20 with connected protective device and conductors — intended for installation inside a distribution board or enclosure, not for wet or outdoor locations.

Frequently asked questions

How do I get current pricing and availability for 5SV6016-7KK06?

Pricing and availability are confirmed at quote time against an RFQ. Submit a request through the storefront; we source through independent distribution channels and provide a current quote.

Will 5SV6016-7KK06 drop into a panel that was specified around 5SY4101-7CV without rewiring?

No — the 5SY4101-7CV is a 1-pole miniature circuit breaker without arc-fault detection, while the 5SV6016-7KK06 is a 1P+N AFDD-MCB combination. Both mount on DIN rail and share the same 18 mm width, but the 5SV6016-7KK06 requires a neutral connection and serves a different protection function (arc-fault plus overcurrent vs. overcurrent only). They are not drop-in substitutes.

What is 5SV6016-7KK06's listed depth (68.5 mm) on this component line?

The listed depth is 68.5 mm, with an installation depth of 70 mm. The unit is 90 mm tall and 18 mm wide (1 modular width).

What compliance documentation does this brand provide for 5SV6016-7KK06 (RoHS, REACH, UL, IEC)?

The device is rated per EN 60898-1 and IEC 60947-2, and is halogen-free and silicon-free. For specific RoHS/REACH/UL declarations, consult the Siemens SENTRON documentation package available via the manufacturer's support portal.