Siemens 5SV6016-7KK10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV6016-7KK10 SENTRON AFDD+MCB, 10A C-curve, 6kA

MPN5SV6016-7KK10
Active

Siemens SENTRON 5SV6016-7KK10, AFDD-MCB combination, 1P+N, 10 A, C-curve, 6 kA, 230 V AC, 1 MW wide, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV6016-7KK10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV6016-7KK10 — Identification
ParameterValue
Product designationAFDD-MCB combination
Product design / constructionCompact unit
5SV6016-7KK10 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth68.5 mm
Installation depth70 mm
5SV6016-7KK10 — Environmental
ParameterValue
IP degree of protectionIP20, with connected protective device and conductors
5SV6016-7KK10 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SV6016-7KK10 is a SENTRON-series AFDD-MCB combination unit — an arc-fault detection device and miniature circuit breaker in one compact housing, 1 MW (18 mm) wide for DIN-rail mounting. It protects a 230 V AC, 10 A final circuit with a C-curve tripping characteristic and a 6 kA breaking capacity rated per both EN 60898-1 and IEC 60947-2. The arc-fault detection function distinguishes dangerous series and parallel arcs from normal switching transients, so it goes into circuits where a plain MCB alone wouldn't catch a smoldering connection — think residential final circuits, hotel rooms, or student housing where the risk of loose terminations or damaged cords is higher.

Snaps onto standard DIN rail (EN 60715), occupies 1 modular width unit (18 mm), and accepts supply from either side — no forced orientation. Depth is 68.5 mm, installation depth 70 mm, so it clears a 100 mm deep enclosure with room for wiring. Ambient range is -40 °C to 75 °C, with 55 °C at 95% relative humidity — fine for an unconditioned electrical room or outdoor-rated enclosure.

The 6 kA breaking capacity at 230 V AC is the same figure under both EN 60898-1 (the residential MCB standard) and IEC 60947-2 (the industrial breaker standard). At 10 A rated current, the power loss per pole is 1.66 W in hot operating state — negligible for thermal budgeting in a multi-way consumer unit.

Halogen-free and silicon-free construction, which matters for clean-room or high-reliability installations where outgassing can't contaminate optics or contacts. The product designation as an AFDD-MCB combination means it carries the relevant IEC/EN standards for both functions — arc-fault detection (IEC 62606) and overcurrent protection (EN 60898-1 / IEC 60947-2).

Frequently asked questions

Where can I buy 5SV6016-7KK10 and how is it quoted?

Sourced and quoted to order against an RFQ through independent industrial distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

What is the difference between 5SV6016-7KK10 and a standard MCB like 5SL6006-7?

The 5SV6016-7KK10 is an AFDD-MCB combination — it includes arc-fault detection on top of overcurrent protection. A standard MCB like 5SL6006-7 only provides overcurrent and short-circuit protection. Both are 1 MW wide, C-curve, 6 kA, and DIN-rail mount, but the AFDD variant adds series-arc detection for circuits where smoldering faults are a concern. The 5SV6016-7KK10 also runs on 50 Hz only, while the 5SL6006-7 accepts 50/60 Hz.

Will 5SV6016-7KK10 drop into a panel designed for 5SL6006-7?

Yes, same footprint — 18 mm width (1 MW), DIN-rail mount, same height and similar depth. The 5SV6016-7KK10 is 68.5 mm deep vs 76 mm for the 5SL6006-7, so it actually leaves more wiring space. No rewiring needed if the circuit requires arc-fault protection.