Siemens SENTRON 5SV6016-7KK32 AFDD+MCB, 32A C-curve 1P+N

MPN5SV6016-7KK32
Active

Siemens SENTRON AFDD+MCB combination, 230 V AC, 32 A, C-curve, 1P+N, 6 kA, compact 1 MW unit.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SV6016-7KK32 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV6016-7KK32 — Identification
ParameterValue
Product design / constructionCompact unit
5SV6016-7KK32 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth68.5 mm
Installation depth70 mm
5SV6016-7KK32 — Environmental
ParameterValue
IP degree of protectionIP20, with connected protective device and conductors
5SV6016-7KK32 — Electrical
ParameterValue
Tripping Characteristic ClassC
Operational current / at AC / rated value32 A

Product details

The Siemens SENTRON 5SV6016-7KK32 is a combined arc-fault detection device (AFDD) and miniature circuit breaker (MCB) in a single compact unit — 1 MW wide, 18 mm per DIN 43880. It carries a 32 A rated operational current at 230 V AC, 50 Hz, with a C tripping characteristic for moderate inrush loads like lighting banks or small motor circuits. Breaking capacity is 6 kA per both IEC 60947-2 and EN 60898-1, sufficient for most residential and light commercial final subcircuits.

This is not a standalone MCB. The AFDD function monitors for series arcs (rated 2 A minimum to 32 A maximum) and parallel arcs (50 A minimum to 500 A maximum) — the ranges that cover loose terminals, crushed cables, and carbonised insulation in a 32 A final circuit. The 1P+N pole design switches the line and switches the neutral, so it fits single-phase subcircuits where neutral isolation is required.

Snap-on DIN rail (REG) mounting per EN 60715, any orientation. The 18 mm width occupies one modular unit, and the 70 mm installation depth leaves clearance behind a standard 80 mm deep enclosure.

Frequently asked questions

What is the breaking capacity of 5SV6016-7KK32?

6 kA per both IEC 60947-2 and EN 60898-1 at 230 V AC.

What is the difference between 5SV6016-7KK32 and a standard MCB like 5SL4106-7CC?

The 5SV6016-7KK32 integrates an arc-fault detection device (AFDD) with the MCB in one 18 mm unit; the 5SL4106-7CC is a standard MCB without AFDD. The 5SL4106-7CC is a 1-pole (1P) device rated 6 A, while the 5SV6016-7KK32 is 1P+N rated 32 A. Both share the same 18 mm width and DIN-rail mounting, but the AFDD function and neutral switching make the 5SV6016-7KK32 a direct replacement only where arc-fault protection is specified.

Where can I buy 5SV6016-7KK32?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

MPN
5SV6016-7KK32