Skip to main content
Siemens 5SV6016-7MC06 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV6016-7MC06 SENTRON AFDD-MCB, 2-pole, 6 kA, Class

MPN5SV6016-7MC06

Siemens SENTRON AFDD-MCB combination, 5SV6016-7MC06, 2-pole 1P+N, 230 V AC, 6 kA per EN 60898-1, Class C, with integrated metering (ammeter, voltmeter, wattmeter, frequency meter, reactive power meter), DIN rail mount, IP20/IP40.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SV6016-7MC06 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SV6016-7MC06 — Identification
ParameterValue
Product designationAFDD-MCB combination
Product design / constructionCompact unit

Mechanical

5SV6016-7MC06 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth68.5 mm
Installation depth70 mm

Environmental

5SV6016-7MC06 — Environmental
ParameterValue
IP degree of protectionIP20, with connected protective device and conductors

Electrical

5SV6016-7MC06 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SV6016-7MC06 is a SENTRON AFDD-MCB combination — an arc-fault detection device and miniature circuit breaker in one compact unit. It's rated 230 V AC, 2-pole (1P+N), with a 6 kA breaking capacity per EN 60898-1 and a Class C tripping characteristic. That means it handles inrush from motorized or fluorescent loads without nuisance trips, and it interrupts arc faults upstream of the load — a single device for both overcurrent and series/parallel arc protection. The unit snaps onto a DIN rail (REG) and occupies just 1 modular width unit (18 mm wide, 90 mm tall, 68.5 mm deep). Mounting position is unrestricted, and the installation depth is 70 mm — it fits standard 80 mm deep enclosures with room for wiring behind the rail.

Metering and display

Built-in metering covers voltage, current, active power, apparent power, reactive power, active energy, line frequency, power factor, temperature, switching cycles, operating hours, tripping events, and warnings — all displayed on the front. Accuracy is 0.5 % for current and voltage, 1 % for active power, per IEC 61557-12, IEC 62053-22, and IEC 62053-23. The measurement is seamless, meaning it logs continuously, not just at trip events. A wireless protocol is supported, so the metering data can be pulled remotely — useful for energy monitoring or predictive maintenance without running additional signal wires.

Frequently asked questions

What is 5SV6016-7MC06 used for?

It's an AFDD-MCB combination: arc-fault detection plus overcurrent protection in one DIN-rail unit. Use it on final subcircuits where both arc faults and overload/short-circuit protection are required — common in residential, commercial, and light industrial distribution boards.

What are the key ratings of 5SV6016-7MC06?

Rated 230 V AC, 2-pole 1P+N, 6 kA breaking capacity per EN 60898-1, Class C tripping characteristic. It includes ammeter, voltmeter, wattmeter, frequency meter, and reactive power meter. Accuracy is 0.5 % for current and voltage, 1 % for active power.

Where can I buy 5SV6016-7MC06?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm offer.

MPN
5SV6016-7MC06