Siemens 5SV6316-6KP16 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SV6316-6KP16 AFDD-RCBO, B-16A, 30mA, 6kA

MPN5SV6316-6KP16
Active

Siemens SENTRON AFDD-RCBO combination, 1P+N, B-curve 16 A, 30 mA Type A, 6 kA breaking capacity, 1 MW wide, DIN-rail mount, order code 5SV6316-6KP16.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV6316-6KP16 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV6316-6KP16 — Identification
ParameterValue
Product design / constructionCompact unit
5SV6316-6KP16 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth68.5 mm
Installation depth70 mm
5SV6316-6KP16 — Environmental
ParameterValue
IP degree of protectionIP20, with connected protective device and conductors
5SV6316-6KP16 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

It protects a single-phase 230 V AC final circuit against arc faults, earth leakage (30 mA, Type A), and overload/short-circuit (B-curve, 16 A).

The B-curve means the magnetic trip operates at 3–5× In (48–80 A for this 16 A unit), so it's the right choice for resistive and general-purpose loads with low inrush — lighting, socket outlets, small appliances. For motor or transformer circuits with higher inrush, a C-curve sibling would be needed.

The 68.5 mm depth plus 70 mm installation depth means it clears most enclosure doors with a 70 mm minimum internal depth. The pigtail neutral conductor requires connection to the neutral busbar — not a plug-in neutral bar.

Frequently asked questions

What is the breaking capacity of 5SV6316-6KP16?

The 5SV6316-6KP16 has a 6 kA breaking capacity per both EN 60898-1 and IEC 60947-2. This is the standard rating for domestic final circuits.

Will 5SV6316-6KP16 drop into a panel specified around 5SV9313-7CN20?

Yes — both are 1-module-wide (18 mm) DIN-rail units with the same 90 mm height and 70 mm installation depth. The 5SV6316-6KP16 is 68.5 mm deep versus 77 mm for the 5SV9313-7CN20, so it fits shallower enclosures. The key difference is the 5SV6316-6KP16 is an AFDD-RCBO combination (arc-fault detection plus residual current) with a B-curve, while the 5SV9313-7CN20 is an RCD-operated circuit breaker (RCBO) with a C-curve — so the tripping characteristic and arc-fault protection differ, but the mechanical footprint is identical.

How do I get current pricing and availability for 5SV6316-6KP16?

The 5SV6316-6KP16 is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.