Skip to main content
Siemens 5SV6316-6KP32 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV6316-6KP32 SENTRON AFDD-RCBO, 32A B 30mA 6kA

MPN5SV6316-6KP32
Active

Siemens SENTRON AFDD-RCBO combination, 230V AC, 32A, 30mA type A, 6kA, 1P+N, B-curve, compact 1MW unit, pigtail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV6316-6KP32 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV6316-6KP32 — Identification
ParameterValue
Product designationAFDD-RCBO combination
Product design / constructionCompact unit
5SV6316-6KP32 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth68.5 mm
Installation depth70 mm
5SV6316-6KP32 — Environmental
ParameterValue
IP degree of protectionIP20, with connected protective device and conductors
5SV6316-6KP32 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

It integrates arc-fault detection (AFDD per IEC 62606), 30 mA type A residual current protection, and a B-curve overcurrent characteristic into one 1-module-wide (18 mm) package that snaps onto a DIN rail. That means a single device covers series arc faults, ground faults, and overload/short-circuit protection for a final subcircuit — no need to stack an AFDD ahead of an RCBO.

Rated 32 A with B-curve tripping: the magnetic trip operates between 3 and 5 times rated current (96–160 A), so it suits resistive and light inductive loads like lighting, socket outlets, and small appliances where inrush is modest.

Depth is 68.5 mm (70 mm installation depth), which clears most standard enclosure gland plates.

Halogen-free and silicon-free construction — important for outgassing-sensitive environments like data centers, medical facilities, or clean rooms.

Frequently asked questions

What is the difference between 5SV6316-6KP32 and a standard RCBO?

The 5SV6316-6KP32 adds integrated arc-fault detection (AFDD) to the RCBO function, so it detects series arcing faults that a standard RCBO cannot. This makes it suitable for circuits where arc-fault protection is required by code (e.g., IEC 60364-7-753 for socket outlets in sleeping rooms or high-risk occupancies).

Will 5SV6316-6KP32 fit in a panel designed for a standard 1-module MCB?

Yes. The 5SV6316-6KP32 occupies one 18 mm modular width and mounts on a DIN rail, the same footprint as a single-pole MCB. Depth of 68.5 mm is within typical enclosure clearance.

Where can I buy the 5SV6316-6KP32?

The 5SV6316-6KP32 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SV6316-6KP32