Siemens 5SV8101-6KK — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV8101-6KK SENTRON Modular RCD, Type A, 0.03-3A

MPN5SV8101-6KK
Active

Siemens SENTRON modular residual current device, digital type A, 5SV8101-6KK, 230V AC, 0.03-3A, time delay 0.02-10s, IP41 front, screw terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV8101-6KK — Electrical Ratings
ParameterValue
Overvoltage categoryIII
5SV8101-6KK — Identification
ParameterValue
Product designationmodular residual current device
Product design / constructionDigital, type A
5SV8101-6KK — Mechanical
ParameterValue
Maximum70 °C
Minimum-20 °C
Width54 mm
Height85 mm
Depth68 mm

Product details

The Siemens 5SV8101-6KK is a SENTRON modular residual current device (RCD) with a digital, type A design. The unit is rated for a 230 V AC operating voltage (range 184 V to 276 V) and can be set to trip anywhere from 0.03 A to 3 A residual current, with an adjustable time delay from 0.02 s to 10 s. That wide trip-current range and the selectable delay make it useful for selective coordination in distribution boards where you need the downstream RCD to clear before the upstream one.

Depth is 68 mm, height 85 mm, so it fits the usual 18 mm pitch enclosure without sticking out past the front cover. Screw-type terminals accept AWG 26 to AWG 14 supply conductors; strip length is 10 mm. The front face carries IP41 protection (splash-proof, tool-resistant), while the connection terminals are IP20 (finger-safe). That split rating is common for panel-mount RCDs — the front can take a light splash during cleaning, but the wiring compartment stays protected inside the enclosure.

Auxiliary contacts and external CT support

This RCD includes two CO (changeover) auxiliary contacts rated at 6 A / 230 V AC, which can be wired for remote tripping indication or status feedback to a PLC. It also supports an external summation current transformer (CT) — compatible types are the 5SV8702-0KK through 5SV8706-0KK series — with a maximum wire length of 10 m between the CT and the device. That external CT capability means the 5SV8101-6KK can monitor circuits where the conductors don't all pass through the internal sensor, such as in retrofit or distributed-load situations.

Frequently asked questions

What is the adjustable time delay range on this RCD?

The time delay is adjustable from 0.02 s (instantaneous) up to 10 s, allowing selective coordination with downstream devices.

What residual current types does this device detect?

As a type A RCD, it detects sinusoidal AC residual currents and pulsating DC residual currents, covering most electronic load scenarios.

Where can I buy the 5SV8101-6KK?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

Will the 5SV8101-6KK fit in a panel designed for a 5SY4301-7CV?

The 5SV8101-6KK and 5SY4301-7CV share the same 54 mm width and DIN-rail mounting, so the physical footprint is compatible. However, the 5SY4301-7CV is a 3-pole MCB (miniature circuit breaker), not an RCD — they serve different protection functions and are not electrically interchangeable.