Siemens 5SV9313-7NK06 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SV9313-7NK06 RCBO, 6 A, Type A, 30 mA, 1P+N

MPN5SV9313-7NK06

Siemens SENTRON 5SV9313-7NK06, RCD-operated circuit breaker (RCBO), 6 A rated at AC, Type A, 30 mA, 1P+N, tripping characteristic C, 4.5 kA SCCR, instantaneous design, 18 mm width, 77 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV9313-7NK06 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV9313-7NK06 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SV9313-7NK06 — Mechanical
ParameterValue
Mounting positionany
Maximum1.5 W
Width18 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SV9313-7NK06 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SV9313-7NK06 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens SENTRON 5SV9313-7NK06 is a 2-pole (1P+N) RCD-operated circuit breaker — an RCBO — combining overcurrent and residual-current protection in a single 18 mm-wide module. Rated 6 A at AC with tripping characteristic C and Type A residual-current sensitivity, it breaks fault currents up to 4.5 kA. The instantaneous design clears short-circuits fast.

Ratings and thermal derating

Above that, the continuous current must be derated: 5.64 A at 40 °C, 5.46 A at 45 °C, 5.22 A at 50 °C, and 5.04 A at 55 °C. Ambient operating range is -25 to +40 °C; storage range is -40 to +75 °C. Mounting position is unrestricted, so it fits horizontal or vertical DIN-rail layouts without further derating.

Installation and wiring

The module occupies one width unit (18 mm) on a DIN rail, with an installation depth of 70 mm and overall depth of 77 mm. Terminals accept solid or stranded conductors from 0.75 to 16 mm². Supply can enter from either top or bottom, simplifying panel layout. Touch protection is built in. The IP20 rating applies only when the distribution board is installed and conductors are connected — not a standalone ingress rating.

Frequently asked questions

What is the depth of 5SV9313-7NK06?

77 mm overall depth; installation depth is 70 mm.

What conductor sizes does 5SV9313-7NK06 accept?

Solid or stranded conductors from 0.75 to 16 mm².

Will 5SV9313-7NK06 drop into a panel designed for 5SL6563-7BB without rewiring?

Both are 18 mm-wide 1P+N RCBOs on the same DIN-rail footprint, but the 5SL6563-7BB is a different series with different terminal layout and tripping characteristics — verify terminal positions and wiring diagram before swapping.