Siemens 5SV9313-7NK10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV9313-7NK10 SENTRON RCBO, 10 A, 30 mA, Type A, 1P+

MPN5SV9313-7NK10

Siemens SENTRON series, RCD-operated circuit breaker (RCBO), 1P+N, 10 A rated current, 30 mA Type A residual current, tripping characteristic C, 4.5 kA per EN 60898, 5 kA per IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV9313-7NK10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV9313-7NK10 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SV9313-7NK10 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SV9313-7NK10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SV9313-7NK10 — Electrical
ParameterValue
Tripping Characteristic ClassC
Operational current / at AC / rated value10 A

Product details

The Siemens 5SV9313-7NK10 is a SENTRON RCD-operated circuit breaker (RCBO) combining overcurrent and residual current protection in a single 18 mm wide module. Rated at 10 A with a 30 mA Type A residual current trip, it protects final circuits against overload, short-circuit, and earth faults — one device, one DIN-rail slot.

The 10 A rated current and C tripping characteristic mean this RCBO is sized for general-purpose final circuits — lighting, small appliances, socket outlets — where inrush from capacitive or motor loads is moderate. Type A detects pulsating DC fault currents from rectifiers or electronic loads, not just pure AC sine-wave faults — a requirement for circuits feeding switched-mode power supplies, LED drivers, or variable-speed drives. Breaking capacity is rated at 4.5 kA per EN 60898 and 5 kA per IEC 60947-2. The EN 60898 figure governs residential and commercial distribution boards; the IEC 60947-2 figure applies when the device is used in industrial switchgear.

Panel integration

Depth is 77 mm, installation depth 70 mm — verify enclosure depth against the gland plate or busbar shroud clearance. Mounting position any, so it can be installed vertically, horizontally, or inverted without derating the thermal trip. Supply cable can enter from top or bottom, which simplifies busbar routing in multi-row distribution boards.

Frequently asked questions

What is 5SV9313-7NK10's listed depth?

Depth is 77 mm; installation depth is 70 mm. Verify enclosure clearance before fitting.

What is 5SV9313-7NK10's listed width?

Width is 18 mm, which equals 1 modular width unit on a standard DIN rail.