Skip to main content
Siemens 5SV9316-0PK10 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SV9316-0PK10 RCBO, 2-pole, 10 A, B-curve, 6

MPN5SV9316-0PK10
Active

Siemens SENTRON 5SV9316-0PK10, RCBO, 2-pole (1P+N), 10 A, B-curve, 6 kA, Type AC, instantaneous, 230/240 VAC, 18 mm wide, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SV9316-0PK10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV9316-0PK10 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SV9316-0PK10 — Mechanical
ParameterValue
Mounting positionany
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SV9316-0PK10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SV9316-0PK10 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

Rated 10 A at 230/240 VAC with a B tripping characteristic, it handles general-purpose lighting and receptacle circuits where fast magnetic trip is needed for short-circuit protection.

Type AC fault-current detection covers sinusoidal AC residual currents, which is the standard for general-purpose circuits without electronic loads generating pulsed DC faults. Thermal derating is published: 10 A at 30 °C, 9.4 A at 40 °C, 8.7 A at 50 °C, and 8.4 A at 55 °C.

Width is 18 mm (1 width unit), depth 77 mm, height 90 mm. Installation depth 70 mm. Mounts in any position on standard DIN rail. Supply connects from below (bottom feed). Touch protection is built in. The part is silicon-free, which matters for potting or conformal-coating compatibility in harsh environments.

Frequently asked questions

What is the breaking capacity of 5SV9316-0PK10?

6 kA per EN 60898 and IEC 60947-2, sufficient for most residential and light commercial sub-distribution boards.

Will 5SV9316-0PK10 drop into a panel that was specified around 5SV9316-1NK06 without rewiring?

Both are 1-pole+N RCBOs in the same 18 mm width, so mechanical fit is the same. However, 5SV9316-1NK06 carries a different current rating and tripping curve; verify the circuit's load and selectivity requirements before swapping.

Where can I buy 5SV9316-0PK10 and how is it quoted?

Sourced to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

MPN