Siemens 5SV9316-1PK16 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV9316-1PK16 SENTRON RCBO, 2-pole, 16A, 30mA, Type

MPN5SV9316-1PK16
Active

Siemens SENTRON 5SV9316-1PK16 RCBO, 2-pole (1P+N), 16 A rated, 30 mA residual current, Type AC, tripping characteristic C, 6 kA breaking capacity, 1 MW modular width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SV9316-1PK16 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV9316-1PK16 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SV9316-1PK16 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SV9316-1PK16 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SV9316-1PK16 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SV9316-1PK16 is a 2-pole (1P+N) SENTRON RCD-operated circuit breaker — an RCBO that combines overcurrent protection and residual current protection in a single 18 mm wide module. The C-curve tripping characteristic means it holds 5–10× In for short-duration inrush, making it a standard fit for general-purpose circuits feeding lighting, socket outlets, and small motor loads in commercial and industrial distribution boards.

One modular width unit (18 mm) snaps onto DIN rail. Depth is 77 mm, installation depth 70 mm — the extra 7 mm is the front projection of the toggle and test button. Mounting position is unrestricted; supply feeds from below per standard practice. IP20 applies once the distribution board is installed and conductors are connected — the RCBO itself is not sealed for wet environments. Touch protection is built in on the line-side terminals.

Thermal derating and environmental limits

At 40 °C it derates to 15.2 A, at 45 °C to 14.72 A, at 50 °C to 14.24 A, and at 55 °C to 13.76 A.

Frequently asked questions

What is the breaking capacity of 5SV9316-1PK16?

6 kA per both EN 60898 and IEC 60947-2, which covers standard residential and light commercial fault levels.

What is the width and modular width of this RCBO?

18 mm wide, which is 1 modular width unit (MW) on standard DIN rail.

Will 5SV9316-1PK16 drop into a panel specified around 5SL6120-7 without rewiring?

Both are 1 MW wide, DIN-rail mount, and 1P+N — so the mechanical fit is the same. But 5SL6120-7 is a plain MCB (no residual current protection), while this is an RCBO with a 30 mA trip. If the panel was wired for a separate RCD plus MCB, swapping to this changes the protection scheme and may require re-termination of the neutral.

Where can I buy 5SV9316-1PK16?

Sourced to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.