Skip to main content
Siemens 5SV9316-6PK10 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV9316-6PK10 SENTRON RCBO, 10A B-curve 30mA 6kA 1P+

MPN5SV9316-6PK10
Active

Siemens SENTRON RCBO, 5SV9316-6PK10, 10A rated, B-curve, 30mA residual current, 6kA breaking capacity, 1P+N, 1 MW wide.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SV9316-6PK10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV9316-6PK10 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SV9316-6PK10 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SV9316-6PK10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SV9316-6PK10 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

The Siemens 5SV9316-6PK10 is a SENTRON RCBO — a combined RCD and MCB in one 1-module-wide (18 mm) package. It provides overcurrent protection (B-curve, 10 A rated) and residual current protection (30 mA, Type A) in a single device, saving DIN-rail space in final distribution boards. The 30 mA trip threshold covers personnel protection against direct contact.

The 10 A rating at 30 °C derates to 9.4 A at 40 °C and 8.4 A at 55 °C — if your panel ambient runs hot, factor that in. The B-curve (3–5 In) means it holds short-duration inrush from resistive and lighting loads but trips fast on a hard fault. Type A residual current detection handles pulsating DC fault waveforms from single-phase rectified loads (SMPS, LED drivers, appliances). The 1P+N form factor switches the line and monitors the neutral; the neutral is not switched.

Width is 18 mm (1 MW), depth 77 mm, height 90 mm. Installation depth 70 mm — ensure the enclosure has enough clearance behind the DIN rail. Rated for ambient -40 °C to 75 °C and up to 95% humidity. Silicon-free construction is noted for applications sensitive to outgassing.

Frequently asked questions

Where can I buy 5SV9316-6PK10 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is 5SV9316-6PK10's listed depth (77 mm) on this component line?

The listed depth is 77 mm, with an installation depth of 70 mm.

What is 5SV9316-6PK10's listed width (18 mm) on this component line?

The width is 18 mm, which is 1 modular width unit (1 MW).

What compliance documentation does this brand provide for 5SV9316-6PK10 (RoHS, REACH, UL, IEC)?

The part is rated per EN 60898 and IEC 60947-2. The evidence does not list RoHS, REACH, or UL documentation specifically; these are typically available from the manufacturer's product page or upon request.

MPN
5SV9316-6PK10