Skip to main content
Siemens 5SV9316-6PK40 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV9316-6PK40 SENTRON RCBO, 40A, 30mA, Type A, 6kA

MPN5SV9316-6PK40
Active

Siemens SENTRON 5SV9316-6PK40, RCD-operated circuit breaker, 2-pole 1P+N, 40 A rated, 30 mA residual current, Type A, 6 kA breaking capacity, tripping characteristic B, instantaneous design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SV9316-6PK40 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SV9316-6PK40 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous

Mechanical

5SV9316-6PK40 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SV9316-6PK40 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SV9316-6PK40 — Electrical
ParameterValue
Tripping Characteristic ClassB

Product details

What this RCBO is and what it protects

The Siemens 5SV9316-6PK40 is a SENTRON RCD-operated circuit breaker (RCBO) combining overcurrent protection and residual current detection in a single 2-pole, 1P+N module. It is rated 40 A at 30 °C with a 30 mA residual trip threshold, Type A (pulsating DC and AC sensitive), and a 6 kA breaking capacity per EN 60898 and IEC 60947-2. The tripping characteristic is B (3-5 In instantaneous magnetic release), so it is sized for resistive and light inductive loads where inrush is modest — think general socket circuits, lighting, and small control transformers in a distribution board.

Fit and panel integration

The 5SV9316-6PK40 occupies one modular width unit (18 mm) on a DIN rail, with a depth of 77 mm and an installation depth of 70 mm. Mounting position is any, and the supply cord enters from below. The IP20 rating applies when installed in a distribution board with conductors connected — standard for enclosed panel use. The silicon-free construction matters for potting or conformal-coating processes in sensitive electronics environments.

Thermal derating and environmental limits

The 40 A rating holds at 30 °C ambient. Derate to 38 A at 40 °C, 36.8 A at 45 °C, 36 A at 50 °C, and 34.8 A at 55 °C. Operating ambient range is -40 to 75 °C, with max 95% humidity. Overvoltage category III and pollution degree 2 — suitable for fixed installation downstream of the main distribution board.

Frequently asked questions

How do I get current pricing and availability for 5SV9316-6PK40?

The 5SV9316-6PK40 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

What is the breaking capacity of 5SV9316-6PK40?

The 5SV9316-6PK40 has a 6 kA breaking capacity rated per both EN 60898 and IEC 60947-2.

What residual current type is 5SV9316-6PK40?

It is Type A, meaning it detects sinusoidal AC residual currents and pulsating DC residual currents up to 30 mA rated fault current.

MPN
5SV9316-6PK40