Siemens 5SV9316-7CN16 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV9316-7CN16 RCD Circuit Breaker, 16 A, Type A, 6 k

MPN5SV9316-7CN16

Siemens SENTRON 5SV9316-7CN16, RCD-operated circuit breaker, 1P+N, 16 A at 30 °C, Type A, 6 kA, 18 mm wide.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SV9316-7CN16 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV9316-7CN16 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SV9316-7CN16 — Mechanical
ParameterValue
Mounting positionany
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SV9316-7CN16 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SV9316-7CN16 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens 5SV9316-7CN16 is a 1P+N RCD-operated circuit breaker from the SENTRON 5SV9 series — an RCBO that combines overcurrent and residual-current protection in a single 18 mm wide module. The Type A fault-current detection means it catches pulsating DC residual currents from electronics, rectifiers, and variable-speed drives, not just sinusoidal AC faults.

At 40 °C it derates to 15.2 A, at 45 °C to 14.72 A, at 50 °C to 14.24 A, and at 55 °C to 13.76 A. If the panel runs warm — say a crowded enclosure near a conveyor drive cabinet — size the branch circuit for the actual ambient, not the 30 °C headline number.

Frequently asked questions

Where can I buy 5SV9316-7CN16?

It is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the difference between 5SV9316-7CN16 and 5SL6550-7BB?

The 5SL6550-7BB is a standard MCB without residual-current protection — it only provides overcurrent and short-circuit protection. The 5SV9316-7CN16 is an RCBO that adds Type A ground-fault detection in the same 18 mm footprint. If the panel needs RCD protection per local code, the 5SV9316-7CN16 replaces both a separate MCB and RCCB in one unit.

What compliance documentation is available for 5SV9316-7CN16?

The part carries a halogen-free and silicon-free construction. It is designed to meet EN 60898 and IEC 60947-2 for breaking capacity, and it is rated for overvoltage category III and pollution degree 2. Specific RoHS/REACH declarations and the manufacturer's declaration of conformity are available on request.

MPN
5SV9316-7CN16