Siemens 5SV9316-7CN16 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SV9316-7CN16 RCD Circuit Breaker, 16 A, Type A, 6 k

MPN5SV9316-7CN16

Siemens SENTRON 5SV9316-7CN16, RCD-operated circuit breaker, 1P+N, 16 A at 30 °C, Type A, 6 kA, 18 mm wide.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Electrical Ratings

5SV9316-7CN16 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII

Identification

5SV9316-7CN16 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous

Mechanical

5SV9316-7CN16 — Mechanical
ParameterValue
Mounting positionany
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth77 mm
Installation depth70 mm

Environmental

5SV9316-7CN16 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Electrical

5SV9316-7CN16 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

What it is and what it does

The Siemens 5SV9316-7CN16 is a 1P+N RCD-operated circuit breaker from the SENTRON 5SV9 series — an RCBO that combines overcurrent and residual-current protection in a single 18 mm wide module. Rated 16 A at 30 °C with a C tripping curve, it handles general-purpose lighting and socket-outlet circuits in residential and light commercial panels. The Type A fault-current detection means it catches pulsating DC residual currents from electronics, rectifiers, and variable-speed drives, not just sinusoidal AC faults. Breaking capacity is 6 kA per both EN 60898 and IEC 60947-2, which covers most domestic and small commercial service entrances.

Thermal derating and panel fit

The 16 A rating holds at 30 °C ambient. At 40 °C it derates to 15.2 A, at 45 °C to 14.72 A, at 50 °C to 14.24 A, and at 55 °C to 13.76 A. If the panel runs warm — say a crowded enclosure near a conveyor drive cabinet — size the branch circuit for the actual ambient, not the 30 °C headline number. The module occupies 1 width unit (18 mm) on a DIN rail, with an installation depth of 70 mm and overall depth of 77 mm. Mounting position is any, and supply can enter from top or bottom, which simplifies wiring in tight gland-plate layouts.

Frequently asked questions

Where can I buy 5SV9316-7CN16?

It is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the difference between 5SV9316-7CN16 and 5SL6550-7BB?

The 5SL6550-7BB is a standard MCB without residual-current protection — it only provides overcurrent and short-circuit protection. The 5SV9316-7CN16 is an RCBO that adds Type A ground-fault detection in the same 18 mm footprint. If the panel needs RCD protection per local code, the 5SV9316-7CN16 replaces both a separate MCB and RCCB in one unit.

What compliance documentation is available for 5SV9316-7CN16?

The part carries a halogen-free and silicon-free construction. It is designed to meet EN 60898 and IEC 60947-2 for breaking capacity, and it is rated for overvoltage category III and pollution degree 2. Specific RoHS/REACH declarations and the manufacturer's declaration of conformity are available on request.