Skip to main content
Siemens 5SV9316-7PK10 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SV9316-7PK10 RCBO, 10 A, 30 mA, Type A, 6 k

MPN5SV9316-7PK10
Active

Siemens SENTRON RCBO, 1P+N, 10 A, 30 mA, Type A, 6 kA, 1 MW, 18 mm wide.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SV9316-7PK10 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV9316-7PK10 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SV9316-7PK10 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SV9316-7PK10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SV9316-7PK10 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens SENTRON 5SV9316-7PK10 is an RCD-operated circuit breaker (RCBO) combining overcurrent protection and residual current detection in a single 18 mm wide module (1 MW). It protects a single-phase final subcircuit at 10 A rated current with a 30 mA residual-current trip threshold, Type A (sensitive to pulsating DC and AC sinusoidal fault currents). Tripping characteristic C means it holds 5–10× In for short magnetic trips — suited to mixed resistive and moderate motor-start loads.

Above that, derate linearly: 9.4 A at 40 °C, 9.1 A at 45 °C, 8.7 A at 50 °C, and 8.4 A at 55 °C. If the panel runs warm — say 45 °C inside the enclosure — the continuous load must stay under 9.1 A to avoid nuisance tripping. The device is silicon-free, which matters in clean-room or potting-sensitive applications.

The 18 mm width (1 MW) leaves room for other modules in a compact sub-distribution board. Supply feeds from below. The IP20 rating applies only when the distribution board is installed with connected conductors — not a standalone outdoor part.

Frequently asked questions

What is the breaking capacity of the 5SV9316-7PK10?

6 kA per both EN 60898 and IEC 60947-2, which covers final subcircuits in domestic and light commercial panels.

What is the residual current rating and type?

30 mA, Type A — detects AC sinusoidal and pulsating DC fault currents, the standard for socket-outlet circuits in most IEC-based installations.

Where can I buy the 5SV9316-7PK10?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What compliance documentation is available for the 5SV9316-7PK10?

The part carries approvals per EN 60898 and IEC 60947-2. RoHS and REACH compliance documentation is typically provided by the manufacturer upon request.

MPN
5SV9316-7PK10