Siemens 5SV9316-7PK16 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SV9316-7PK16 RCBO, 2-pole, 16 A, 30 mA, Typ

MPN5SV9316-7PK16
Active

Siemens SENTRON 5SV9316-7PK16, RCBO, 2-pole, 16 A, 30 mA, Type A, 6 kA, 1 MW, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SV9316-7PK16 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SV9316-7PK16 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SV9316-7PK16 — Mechanical
ParameterValue
Mounting positionany
Width in modular units1
Maximum75 °C
Minimum-40 °C
Width18 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SV9316-7PK16 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SV9316-7PK16 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

The Siemens SENTRON 5SV9316-7PK16 is a 2-pole RCBO — an RCD-operated circuit breaker combining overcurrent and residual current protection in a single 18 mm wide module. It is rated 16 A at 30 °C with a 30 mA residual current trip threshold, Type A (pulsating DC and AC sensitive). The tripping characteristic is Class C, instantaneous design, meaning it trips on short-circuit without intentional delay. Breaking capacity is 6 kA per both EN 60898 and IEC 60947-2, which covers the majority of residential and light commercial distribution board fault levels.

Above that, the continuous current must be derated: 15.2 A at 40 °C, 14.72 A at 45 °C, 14.24 A at 50 °C, and 13.76 A at 55 °C. The maximum operating ambient is 75 °C, minimum -40 °C.

DIN-rail footprint and installation

The 5SV9316-7PK16 occupies 1 modular width unit (18 mm) on a standard DIN rail. Depth is 77 mm, height 90 mm, installation depth 70 mm. The supply cord connects from below. Touch protection is provided per the product feature.

Frequently asked questions

What is the breaking capacity of 5SV9316-7PK16?

The breaking capacity is 6 kA per both EN 60898 and IEC 60947-2, which covers standard residential and light commercial distribution board fault levels.

What is the residual current type and rating?

It is Type A (sensitive to pulsating DC and AC residual currents) with a rated tripping fault current of 30 mA.

How do I get current pricing and availability for 5SV9316-7PK16?

The part is sourced to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN
5SV9316-7PK16