Skip to main content
Siemens 5SY1710-4 — 1-Pole MCB (DIN Rail)

Siemens 5SY1710-4 SENTRON Device Circuit Breaker, F2 10A 1P+

MPN5SY1710-4
Active

Siemens SENTRON 5SY1710-4, device circuit breaker, 1-pole with auxiliary switch NO contact, characteristic F2, 10 A, 230 V AC 50/60 Hz, 60 V DC, Icn 3 kA AC per IEC 60934.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY1710-4 — Identification
ParameterValue
Product designationDevice protection switch
Brand nameSENTRON
Number of poles1
Pole design1P+AS
5SY1710-4 — Electrical & Protection
ParameterValue
Tripping characteristic classF2
Overvoltage categoryIII
5SY1710-4 — Mounting & Connection
ParameterValue
Mounting positionHorizontal/vertical
Fastening methodDIN rail
Combined terminal, topNo
Combined terminal, bottomNo
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.70 °C
SealableYes
5SY1710-4 — Environmental
ParameterValue
IP protection classIP20
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

Its F2 tripping characteristic provides a defined overload and short-circuit response curve, with a rated current of 10 A at 230 V AC and 60 V DC, and a breaking capacity of 3 kA AC per IEC 60934 and UL1077.

The 1P+AS pole configuration means the auxiliary switch tracks the main contact position — useful for remote status feedback or interlock circuits without adding an external auxiliary block.

The F2 characteristic is a fast-acting curve suitable for protecting sensitive semiconductor loads or control transformers. Rated for 10 A at 230 V AC and 60 V DC, with a maximum of 72 V DC and 250 V AC under single-phase operation.

Rated for ambient temperatures from -40 °C to 70 °C, with derating above 30 °C depending on humidity (30 °C @ 85% rF, 60 °C @ 20% rF). IP20 finger-safe terminals. Halogen-free and silicon-free construction. Complies with IEC/DIN EN 60934 and UL1077; vibration resistance per IEC 60068-2-6.

Frequently asked questions

What are the key ratings of the 5SY1710-4?

Rated 10 A with F2 characteristic, 230 V AC / 60 V DC, breaking capacity 3 kA AC per IEC 60934. One pole with integrated auxiliary switch NO contact.

What standards does 5SY1710-4 comply with?

It complies with IEC / DIN EN 60934 and UL1077, with IP20 protection, halogen-free and silicon-free construction.

MPN
5SY1710-4