Skip to main content
Siemens 5SY1716-2 — 1-Pole MCB (DIN Rail)

Siemens 5SY1716-2 SENTRON Device Protection Switch, 1P+AS, 1

MPN5SY1716-2
Active

Siemens SENTRON 5SY1716-2, device protection switch, 1-pole with auxiliary switch NO contact, characteristic F1, 16 A, 230 V AC, 60 V DC, 3 kA Icn AC per IEC 60934.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY1716-2 — Identification
ParameterValue
Product designationDevice protection switch
Brand nameSENTRON
Number of poles1
Pole design1P+AS
5SY1716-2 — Electrical & Protection
ParameterValue
Tripping characteristic classF1
Overvoltage categoryIII
5SY1716-2 — Mounting & Connection
ParameterValue
Mounting positionHorizontal/vertical
Fastening methodDIN rail
Combined terminal, topNo
Combined terminal, bottomNo
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.70 °C
SealableYes
5SY1716-2 — Environmental
ParameterValue
IP protection classIP20
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SY1716-2 is a SENTRON device protection switch — a 1-pole unit with an integrated auxiliary normally-open contact, rated 16 A with characteristic F1. Per the datasheet, it interrupts fault currents up to 3 kA AC per IEC 60934 and also carries a UL1077 listing, so it's accepted in both IEC and North American panel builds. The F1 curve is a fast-acting characteristic with a defined short-circuit let-through, intended for semiconductor or sensitive load protection where standard B/C curves would pass too much energy before tripping.

Snaps onto DIN rail per, occupies a single modular width unit (18 mm wide per). Mounts horizontally or vertically. IP20 finger-safe terminals; this is an enclosed-panel part, not for washdown environments.

Electrical ratings and operating conditions

Rated AC operating voltage is 230 V, with a maximum of 250 V in single-phase operation. DC side is rated 60 V, maximum 72 V. Supply frequency is 50/60 Hz. Ambient temperature range is -40 °C to +70 °C, with derating per the influence curve: 30 °C at 85% relative humidity, 60 °C at 20% rF.

Frequently asked questions

What is the 5SY1716-2 used for?

It is a device protection switch (supplementary protector) with an auxiliary NO contact, rated 16 A characteristic F1. It protects downstream semiconductor or sensitive loads in control panels, mounted on DIN rail. The F1 curve provides fast interruption with limited let-through energy, distinct from standard B/C curves.

What compliance standards does the 5SY1716-2 meet?

It is certified to IEC / DIN EN 60934 (equipment circuit breakers) and UL1077 (supplementary protectors for North America). The housing is halogen-free and silicon-free.

How do I get pricing and availability for the 5SY1716-2?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

MPN
5SY1716-2