Skip to main content
Siemens 5SY1716-4 — 1-Pole MCB (DIN Rail)

Siemens 5SY1716-4 SENTRON Device Protection Switch, 16 A, F2

MPN5SY1716-4
Active

Siemens SENTRON device protection switch, 1-pole with auxiliary switch (1P+AS), 16 A AC, F2 tripping characteristic, 60 V DC, IP20, standard rail mount, 18 mm width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY1716-4 — Identification
ParameterValue
Product designationDevice protection switch
Brand nameSENTRON
Number of poles1
Pole design1P+AS
5SY1716-4 — Electrical & Protection
ParameterValue
Tripping characteristic classF2
Overvoltage categoryIII
5SY1716-4 — Mounting & Connection
ParameterValue
Mounting positionHorizontal/vertical
Fastening methodstandard rail
Combined terminal, topNo
Combined terminal, bottomNo
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.70 °C
SealableYes
5SY1716-4 — Environmental
ParameterValue
IP protection classIP20
Pollution degree2
Halogen-freeYes
Silicone-freeYes

Product details

The 5SY1716-4 is a SENTRON device protection switch — a 1-pole unit with an integrated auxiliary switch (1P+AS), rated 16 A at AC and 60 V DC. The F2 tripping characteristic is a fast-acting curve that sits between the standard B and C curves; it trips within 0.1–5 seconds at 4–7 times rated current, making it suited for protecting semiconductor loads, control transformers, and sensitive electronics where a standard MCB would be too slow. The auxiliary switch provides a separate signal contact for remote status monitoring or PLC input — useful in a panel where you need to know the breaker has opened without running a separate sensor. Rated to IEC / DIN EN 60934 and UL1077, this is a supplementary protector, not a branch-circuit rated device. In a UL panel, it goes downstream of a branch-circuit overcurrent device.

In a warm cabinet, the continuous current drops: 15.47 A at 35 °C, 14.67 A at 40 °C, 14.25 A at 45 °C, 13.82 A at 50 °C, 13.38 A at 55 °C, and 12.93 A at 60 °C (–). If your panel ambient runs 50 °C, plan for a 13.8 A continuous load maximum — not 16 A. The device also carries a humidity derating: 30 °C at 85% rF, 60 °C at 20% rF.

Integration notes

Fastens on standard DIN rail. The auxiliary switch (1P+AS) is wired separately from the main load circuit; it changes state when the breaker trips or is manually switched off. No neutral conductor switching, no combined top or bottom terminals — line and load are separate.