Siemens 5SY3006-7KL

Siemens 5SY3006-7KL SENTRON MCB, 1P+N, C-Curve 6 A, 4.5 kA

MPN 5SY3006-7KL

Siemens SENTRON 5SY3006-7KL miniature circuit breaker, 1P+N, C-curve 6 A, 4.5 kA breaking capacity at 230 V AC, 18 mm wide, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SY3006-7KL specifications
ParameterValue
IP ratingIP20
Mountingstandard rail
Depth76 mm
Width18 mm
Height90 mm

Product details

Siemens SENTRON 5SY3006-7KL — 1P+N MCB, C-Curve 6 A, 4.5 kA

The Siemens SENTRON 5SY3006-7KL is a 1-pole+N miniature circuit breaker rated 6 A at 230 V AC with a C-trip curve and 4.5 kA breaking capacity per EN 60898. The C-curve (trips at 5–10× rated current) is the standard choice for general-purpose branch circuits feeding resistive and moderate-inductive loads like lighting, small motors, and control transformers — the 6 A rating protects a 230 V AC single-phase circuit drawing up to about 1.38 kVA. This is a 1P+N design: the neutral pole is switched simultaneously with the live pole, so both conductors are isolated when the breaker trips or is manually opened. That makes it suitable for final sub-circuits where a switched neutral is required by local wiring rules. The neutral pole is not overcurrent-protected — it follows the live pole's state.

One width unit (18 mm) — no side space lost. Terminal torque spec is 17.7 to 22.1 lbf·in (2.0–2.5 N·m). Mounting position is unrestricted; the breaker can be installed horizontally or inverted if the panel layout demands it. Halogen-free and silicon-free construction — no corrosive off-gassing if the breaker arcs internally. Sealable with a lead or tag, which helps meet lockout/tagout requirements on commercial or industrial panels.

For selectivity with an upstream 63 A or 100 A main breaker, verify that the let-through energy of the upstream device stays below the 5SY's withstand — typical for a residential or small commercial distribution board. Energy limiting class 3 means it restricts the peak current and arc energy on a short-circuit, reducing stress on downstream wiring and loads. Not intended for frequent switching as a load disconnect.

MPN
5SY3006-7KL