Siemens 5SY3016-6KL — 1-Pole MCB (DIN Rail)

Siemens 5SY3016-6KL SENTRON MCB, 1P+N 16A B-curve 4.5kA

MPN5SY3016-6KL

Siemens SENTRON 5SY3016-6KL, miniature circuit breaker, 1P+N, 16 A, B characteristic, 4.5 kA, 230 V AC, 18 mm wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY3016-6KL — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
5SY3016-6KL — Electrical & Protection
ParameterValue
Tripping characteristic classB
Rated value (EN 60898)4.5 kA
Overvoltage categoryIII
5SY3016-6KL — Mounting & Connection
ParameterValue
Mounting positionany
Combined terminal, topNo
Combined terminal, bottomNo
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Torque, min.17.7 lbf·in
Torque, max.22.1 lbf·in
SealableYes
5SY3016-6KL — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Halogen-freeYes
Silicone-freeYes

Product details

Siemens 5SY3016-6KL — SENTRON 1P+N MCB, 16 A B-curve, 4.5 kA

The Siemens 5SY3016-6KL is a SENTRON miniature circuit breaker (MCB) rated 16 A at 230 V AC with a B tripping characteristic and a 4.5 kA breaking capacity per EN 60898. The 1P+N pole configuration switches the line and switches the neutral — the N pole is switched but not protected, which is the standard arrangement for single-phase final subcircuits in TN and TT systems where overcurrent protection on the neutral is not required. The B curve (3–5× In instantaneous trip) suits resistive and general-purpose loads with low inrush — lighting, socket outlets, small appliances — where a C curve would nuisance-trip on start-up.

Mounting position any; no derating for horizontal or inverted orientation. Terminal torque range 17.7 to 22.1 lbf·in — a standard screwdriver bit handles it.

Construction and compliance

Halogen-free and silicon-free construction — no silicone outgassing that could contaminate relay contacts or optics in a mixed panel. Sealable with a lead seal (tamper-evident cover included). Vibration-resistant per IEC 60068-2-6. Touch protection on the terminals is standard.

Frequently asked questions

What is the breaking capacity of 5SY3016-6KL?

4.5 kA rated short-circuit capacity per EN 60898 at 230 V AC. That is the standard domestic and light-commercial interrupting rating for this class — sufficient for most TN final subcircuits, but verify against the prospective short-circuit current at the point of installation.

Where can I buy the Siemens 5SY3016-6KL?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.

What is the difference between 5SY3016-6KL and 5SY6008-7?

The 5SY6008-7 is a C-curve 8 A MCB with a 6 kA breaking capacity. The 5SY3016-6KL is a B-curve 16 A with a 4.5 kA rating. Both are 1P+N, 18 mm wide, same depth, same SENTRON family. They share the same footprint and terminal torque range, so a panel wired for one can accept the other without rewiring — but the trip curve and current rating differ, so the substitution must be validated against the circuit design.