Skip to main content
Siemens 5SY3104-7 — 1-Pole MCB (DIN Rail)

Siemens 5SY3104-7 SENTRON MCB, 1P C-4A, 6 kA IEC

MPN5SY3104-7

Siemens SENTRON 5SY3 series, miniature circuit breaker, 1-pole, C characteristic, 4 A rated current, 6 kA breaking capacity per IEC 60947-2, 4.5 kA per EN 60898.

$29.01Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY3104-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
5SY3104-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)4.5 kA
Overvoltage categoryIII
5SY3104-7 — Mounting & Connection
ParameterValue
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY3104-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

It breaks 6 kA per IEC 60947-2 and 4.5 kA per EN 60898 — enough for most final subcircuits in commercial and light industrial panels. Rated for any mounting position, pollution degree 3, overvoltage category III — fits standard distribution boards and sub-panels without special derating.

The 6 kA rating under IEC 60947-2 gives headroom over the 4.5 kA EN 60898 figure — the higher standard applies when the breaker is used as a standalone device in industrial control panels, not just as a domestic consumer unit. Energy limiting class 3 means it restricts let-through energy well — important for downstream component protection and cable coordination in dense panels.

This is a current-production part in the Siemens SENTRON 5SY3 family. No phase-out or last-time-buy has been announced.

Operating temperature range -40 °C to 75 °C, with humidity derating above 55 °C (max 95% RH at 55 °C, dropping to 35% at 75 °C). Halogen-free and silicon-free construction, sealable for tamper evidence. Combined top and bottom terminals simplify busbar feed-through.

Frequently asked questions

What is the breaking capacity of 5SY3104-7?

6 kA per IEC 60947-2 at 400 V AC, 4.5 kA per EN 60898, and 15 kA at 72 V DC per IEC 60947-2. The UL/CSA rating is 5 kA at 400 V AC.

What does the C-curve mean on this breaker?

The C tripping characteristic means the magnetic trip operates at 5 to 10 times rated current (20–40 A for this 4 A unit). That suits loads with moderate inrush — contactors, small motors, lighting — but avoids nuisance tripping on brief surges.

Where can I buy 5SY3104-7?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

MPN
5SY3104-7