Siemens 5SY3125-6 — 1-Pole MCB (DIN Rail)

Siemens 5SY3125-6 SENTRON MCB, 1P, 25 A, B Curve, 4.5 kA

MPN5SY3125-6

Siemens SENTRON 5SY3 series, miniature circuit breaker (MCB), 1-pole, 25 A rated current, B tripping characteristic, 4.5 kA breaking capacity per EN 60898, 6 kA per IEC 60947-2, 400 V AC, 72 V DC, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY3125-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
5SY3125-6 — Electrical & Protection
ParameterValue
Tripping characteristic classB
Rated value (EN 60898)4.5 kA
Overvoltage categoryIII
5SY3125-6 — Mounting & Connection
ParameterValue
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
SealableYes
5SY3125-6 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Halogen-freeYes
Silicone-freeYes

Product details

What this MCB does on the line

The Siemens 5SY3125-6 is a 1-pole SENTRON miniature circuit breaker rated 25 A with a B tripping characteristic, meaning it trips at 3–5× rated current — the standard choice for residential and light commercial lighting and socket-outlet circuits where inrush is low. It breaks 4.5 kA per EN 60898 and 6 kA per IEC 60947-2, so it handles typical domestic and industrial fault levels up to that point without cascading upstream. The 400 V AC rating covers single-phase line-to-neutral or line-to-line applications; the 72 V DC maximum extends it to control circuits and DC auxiliary supplies.

IP20 with connected conductors; install in a cabinet that keeps the front accessible for the sealable toggle.

Breaking capacity across standards

This MCB carries three breaking-capacity ratings because it is certified to multiple standards. Per EN 60898 (the household standard) it is 4.5 kA at 400 V AC. For DC circuits per IEC 60947-2 it is 15 kA at 72 V. Under UL 1077 and CSA C22.2 No. 235 it is 5 kA at 400 V AC. The energy limiting class is 3, so it limits let-through energy well enough to protect downstream components in a selective coordination scheme.

Humidity tolerance: 95 % at 55 °C, derating to 35 % at 75 °C.

Frequently asked questions

How do I get current pricing and availability for 5SY3125-6?

Submit an RFQ through the storefront. Pricing and stock levels are confirmed at quote time; the part is sourced to order through independent distribution channels.

Will 5SY3125-6 drop into a panel specified around 5SY3132-6 without rewiring?

Both are 1-pole SENTRON 5SY3 MCBs with the same 18 mm width, 90 mm height, and 76 mm depth, so the mechanical fit is identical. The difference is the current rating: 5SY3125-6 is 25 A, while 5SY3132-6 is 32 A. If the panel was wired for 32 A (larger conductor or higher load), dropping in a 25 A breaker may nuisance-trip under the original load. Check the branch-circuit load before swapping.

What is 5SY3125-6's listed depth?

76 mm total depth, with a 70 mm installation depth behind the panel door.

What conductor sizes does 5SY3125-6 accept?

Solid or stranded copper from 0.75 mm² up to 35 mm².

What compliance documentation does Siemens provide for 5SY3125-6?

The MCB carries ratings per EN 60898, IEC 60947-2, UL 1077, and CSA C22.2 No. 235. It is halogen-free and silicon-free. Standard RoHS and REACH declarations are available from Siemens documentation.

MPN
5SY3125-6