Siemens 5SY3201-7 — 2-Pole MCB (DIN Rail)

Siemens 5SY3201-7 SENTRON MCB, 1A C-Curve 2P 400V AC

MPN5SY3201-7

Siemens SENTRON 5SY3 series, miniature circuit breaker, 5SY3201-7, 1 A rated current, C characteristic, 2-pole, 400 V AC, 4.5 kA (EN 60898) / 6 kA (IEC 60947-2).

$73.51Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY3201-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
5SY3201-7 — Electrical
ParameterValue
Number of poles2
5SY3201-7 — Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SY3201-7 — Mechanical
ParameterValue
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Protection degree (IP)IP20, with connected conductors

Product details

1 A C-curve MCB for 400 V AC branch circuits

It protects branch circuits at 400 V AC, with a breaking capacity of 4.5 kA per EN 60898 and 6 kA per IEC 60947-2 — the higher IEC figure gives you headroom for industrial panel coordination where the prospective fault current sits above the domestic standard. At 1 A it suits control transformers, PLC power supplies, or instrument loops where a B-curve would nuisance-trip on the inrush and a D-curve would delay too long for sensitive electronics.

Mounts via the quick-assembly system (DIN rail clip) in any position — no derating for horizontal or inverted orientation. Installation depth is 70 mm; the overall depth including terminals is 76 mm, which clears most standard 80 mm deep enclosures. Width is 36 mm (2 width units), height 90 mm. Combined terminals top and bottom mean you can feed from either end without swapping hardware. Touch protection is built in; the unit is sealable for panel lockout programs.

Environmental limits and DC rating

Humidity derating applies: 95% RH up to 55 °C, then 55% RH at 70 °C, and 35% RH at 75 °C — relevant if the panel sits in a non-conditioned washdown area or outdoor cabinet. That covers 48 VDC control bus protection and some 60 VDC solar-combiner applications, but verify polarity and arc extinction for your specific DC load.

Frequently asked questions

What is the breaking capacity of 5SY3201-7?

4.5 kA per EN 60898 and 6 kA per IEC 60947-2 at 400 V AC. For DC applications it is rated 15 kA at 72 V per IEC 60947-2. Under UL 1077 / CSA 22.2 No. 235 it carries 5 kA.

Will 5SY3201-7 drop into a panel specified around 5SY3132-6?

Both are 2-pole SENTRON 5SY3 series MCBs with the same 36 mm width, 90 mm height, and 76 mm depth — same DIN rail footprint, same terminal range. The difference is rating: 5SY3201-7 is 1 A C-curve; 5SY3132-6 is a different current and characteristic. If the panel was wired for a higher-rated breaker, swapping to 1 A without recalculating the load and wire sizing is not safe.

How do I get pricing and availability for 5SY3201-7?

Sourced and quoted to order against an RFQ through independent distribution. Current pricing and stock levels are confirmed at quote time — submit an RFQ for a firm commercial offer.