Siemens 5SY3225-6 SENTRON MCB, 25A, 2-Pole, B-Curve, 4.5kA

MPN5SY3225-6

Siemens SENTRON 5SY3 series, miniature circuit breaker, 2-pole, 25 A, B-curve, 400 V AC, 4.5 kA (EN 60898) / 6 kA (IEC 60947-2), 72 V DC max, 2 width units, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY3225-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
5SY3225-6 — Electrical
ParameterValue
Number of poles2
5SY3225-6 — Protection
ParameterValue
Tripping characteristic classB
Overvoltage categoryIII
5SY3225-6 — Mechanical
ParameterValue
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Protection degree (IP)IP20, with connected conductors

Product details

The Siemens 5SY3225-6 is a 2-pole miniature circuit breaker from the SENTRON 5SY3 family, rated 25 A at 400 V AC with a B tripping characteristic — magnetic trip between 3 and 5 times rated current, so it's suited for resistive and general-purpose loads where inrush is low (lighting, heaters, control circuits), not motor starting. Breaking capacity is 4.5 kA per EN 60898 and 6 kA per IEC 60947-2; at DC it's rated 15 kA max 72 V. The 36 mm width (2 width units) snaps onto a DIN rail via the quick assembly system — any mounting position works, and the terminals accept solid or stranded wire from 0.75 up to 35 mm², so it covers most panel wiring sizes without adapters.

Deployment context — where this breaker lives

The sealable feature (padlockable toggle) lets a site lock it in the OFF position for LOTO procedures. Halogen-free and silicon-free construction matters in clean-room or semiconductor fab environments where outgassing contaminates processes.

Frequently asked questions

Where can I buy 5SY3225-6 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing.

What is 5SY3225-6's listed depth (76 mm) on this component line?

The depth is 76 mm, width 36 mm (2 width units), height 90 mm — standard DIN-rail form factor.

What is 5SY3225-6's listed solid (0.75... 35 mm²) on this component line?

The terminals accept solid and stranded conductors from 0.75 mm² up to 35 mm², covering most panel wiring sizes without adapters.

Will 5SY3225-6 drop into a panel that was specified around 5SY3132-6 without rewiring?

Both are 2-pole SENTRON 5SY3 breakers on the same DIN-rail footprint — same width (36 mm), same terminal range (0.75–35 mm²), same mounting. The difference is the current rating: 5SY3225-6 is 25 A, 5SY3132-6 is 32 A. If the circuit load is under 25 A and the trip curve (B) matches, it's a direct swap without rewiring.

What compliance documentation does this brand provide for 5SY3225-6 (RoHS, REACH, UL, IEC)?

The breaker carries ratings per EN 60898 (4.5 kA), IEC 60947-2 (6 kA), and UL 1077 / CSA C22.2 No.235 (5 kA). It is halogen-free and silicon-free. For specific RoHS/REACH declarations, request the manufacturer's compliance certificate at quote time.

MPN