Skip to main content
Siemens 5SY3232-6 — 2-Pole MCB (DIN Rail)

Siemens 5SY3232-6 SENTRON MCB, 32 A, 2-Pole, B-Curve, 6 kA

MPN5SY3232-6

Siemens SENTRON 5SY3 series miniature circuit breaker, 5SY3232-6, 2-pole, B characteristic, 32 A rated current, 400 V AC, 4.5/6 kA breaking capacity.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY3232-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
5SY3232-6 — Electrical
ParameterValue
Number of poles2
5SY3232-6 — Protection
ParameterValue
Tripping characteristic classB
Overvoltage categoryIII
5SY3232-6 — Mechanical
ParameterValue
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors

Product details

It protects branch circuits against overload and short-circuit in 400 V AC systems, with a breaking capacity of 4.5 kA per EN 60898 and 6 kA per IEC 60947-2. Mounting is quick-assembly onto DIN rail; the 36 mm width (2 width units) fits standard distribution boards.

The 5SY3232-6 carries dual breaking-capacity ratings: 4.5 kA under EN 60898 (the standard for household and similar installations) and 6 kA under IEC 60947-2 (the industrial standard for low-voltage switchgear). For DC circuits, it can interrupt 15 kA at up to 72 V DC per IEC 60947-2. UL 1077 and CSA C22.2 No. 235 recognition at 5 kA means it is accepted in North American supplementary-protection applications — useful for a panel that ships globally. Energy limiting class 3 means it restricts let-through energy enough to protect downstream equipment under short-circuit conditions. Overvoltage category III confirms it is rated for fixed-installation use, not just socket outlets.

Rated for ambient temperatures from -40 °C to 75 °C, with humidity derating above 55 °C (95% RH up to 55 °C, 55% RH at 70 °C, 35% RH at 75 °C).

Frequently asked questions

What is the breaking capacity of 5SY3232-6?

It is rated 4.5 kA per EN 60898, 6 kA per IEC 60947-2, and 15 kA at 72 V DC per IEC 60947-2. For UL/CSA applications it carries 5 kA.

What is the difference between 5SY3232-6 and 5SY4140-7?

The 5SY4140-7 is a 1-pole breaker with a higher 40 A rating and C-curve, while the 5SY3232-6 is a 2-pole B-curve at 32 A. They share the same 5SY platform and DIN-rail footprint, but the pole count, current, and trip characteristic differ — they are not drop-in replacements without rewiring.

Where can I buy the 5SY3232-6?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SY3232-6