Siemens 5SY3250-6 — 2-Pole MCB (DIN Rail)

Siemens 5SY3250-6 SENTRON MCB, 50A, 2-Pole, B-Curve, 6kA IEC

MPN5SY3250-6

Siemens SENTRON 5SY3 series, miniature circuit breaker, 2-pole, 50 A, B-curve, 4.5 kA (EN 60898) / 6 kA (IEC 60947-2), 400 V AC, 72 V DC max, 2 width units (36 mm), IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY3250-6 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
5SY3250-6 — Electrical
ParameterValue
Number of poles2
5SY3250-6 — Protection
ParameterValue
Tripping characteristic classB
Overvoltage categoryIII
5SY3250-6 — Mechanical
ParameterValue
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Protection degree (IP)IP20, with connected conductors

Product details

That B-curve means it trips at 3–5× rated current — standard for general-purpose lighting and distribution circuits where you don't want nuisance trips from motor inrush. The 4.5 kA breaking capacity per EN 60898 and 6 kA per IEC 60947-2 at 400 V AC tell you it can safely interrupt a fault up to those levels without welding contacts or cascading upstream. For DC circuits it's rated 15 kA at 72 V max per IEC 60947-2, and 5 kA per UL 1077 / CSA C22.2 No.235 — useful if you're feeding a DC bus or control supply off the same panel. The 2-pole (2P) configuration with 36 mm width (2 width units) snaps onto standard DIN rail. Mounting position is any, so you can lay it sideways in a tight gland plate area if needed. Terminal capacity accepts 0.75 to 35 mm² solid or stranded — covers everything from a 1.5 mm² control circuit tail up to a 35 mm² main feeder. Combined terminals top and bottom mean you can feed from either end without reconfiguring.

Height 90 mm, width 36 mm. The 2-pole body leaves room for a 4-pole isolator or a second MCB in the same 72 mm wide slot. Ambient temperature range -25 to +55 °C, storage -40 to +75 °C.

Rated per EN 60898 (4.5 kA) and IEC 60947-2 (6 kA) for AC circuits, plus UL 1077 and CSA C22.2 No.235 (5 kA) for North American acceptance. Sealable with a lockable cover for isolation lockout/tagout procedures.

Frequently asked questions

What is the breaking capacity of 5SY3250-6 at 400 V AC?

4.5 kA per EN 60898 and 6 kA per IEC 60947-2 at 400 V AC. For DC circuits it's rated 15 kA at 72 V max per IEC 60947-2, and 5 kA per UL 1077 / CSA C22.2 No.235.

What conductor sizes does 5SY3250-6 accept?

Solid or stranded conductors from 0.75 mm² up to 35 mm². The combined terminals top and bottom accept the same range, so you can feed from either end.

Will 5SY3250-6 drop into a panel that was specified around 5SY3132-6 without rewiring?

Both are 2-pole SENTRON MCBs on the same 36 mm footprint, same DIN-rail mount, same terminal range. The 5SY3250-6 is a 50 A B-curve; the 5SY3132-6 is a 32 A C-curve. If the panel was wired for 32 A and the bus bar is sized for that, dropping in a 50 A breaker without upgrading the downstream conductor and bus rating would be a code violation. Mechanically it fits; electrically you need to verify the wire sizing and coordination study.

Where can I buy 5SY3250-6 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here.