Siemens 5SY4103-7KK11 — 1-Pole MCB (DIN Rail)

Siemens 5SY4103-7KK11 SENTRON MCB, 1P C-curve 3A, 10/35kA

MPN5SY4103-7KK11

Siemens SENTRON 5SY4103-7KK11, 1-pole miniature circuit breaker, C characteristic, 3 A rated current, 10 kA (EN 60898) / 35 kA (IEC 60947-2) breaking capacity, IP20, halogen-free, for railway applications.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY4103-7KK11 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Application suitabilityMechanical engineering / industry
5SY4103-7KK11 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Rated value (EN 60898)10 kA
Energy limitation class3
Overvoltage categoryIII
5SY4103-7KK11 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY4103-7KK11 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The C-curve (tripping characteristic class C) means the breaker holds 5–10× rated current for short periods before tripping magnetically — typical for motor-starter and lighting circuits where inrush is moderate. At 3 A rated current, it is sized for small loads: control transformers, contactor coils, or single-phase auxiliary circuits drawing under 2.4 A continuous at 40 °C ambient (the derated value at 40 °C is 2.82 A).

Temperature derating — don't ignore it

This breaker carries a full temperature-derating table from the factory. At 35 °C it holds the full 3 A; at 40 °C it drops to 2.82 A; at 45 °C to 2.72 A; at 50 °C to 2.62 A; at 55 °C to 2.52 A; at 60 °C to 2.41 A.

Mounting position is unrestricted — horizontal, vertical, or inverted all within spec. The combined terminal at top and bottom accepts both busbar and conductor connections without re-termination.

Construction and compliance notes

Halogen-free and silicon-free construction, with sealable terminals and touch protection. Designed for railway applications per the product designation, so it meets the vibration and environmental endurance typical of EN 50155-derived requirements. The energy limitation class is 3, which limits let-through energy in a fault event.

Frequently asked questions

What is the breaking capacity of 5SY4103-7KK11?

10 kA per EN 60898 and 35 kA per IEC 60947-2. The higher 35 kA rating applies when the breaker is used under IEC 60947-2 conditions, typically in industrial distribution where fault currents are larger.

What is the temperature derating for this breaker?

At 40 °C the rated current derates to 2.82 A; at 50 °C to 2.62 A; at 60 °C to 2.41 A. The full derating curve is published from 35 °C to 60 °C.

Where can I buy 5SY4103-7KK11?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 5SY4103-7KK11 drop into a panel specified around 5SY4101-7CV?

Both are 1-pole SENTRON MCBs with the same 18 mm width and DIN-rail mounting, so mechanical fit is identical. The difference is rating: 5SY4103-7KK11 is 3 A C-curve; 5SY4101-7CV is a different current rating. Verify the load current before swapping.

What compliance documentation does Siemens provide for 5SY4103-7KK11?

The breaker carries EN 60898 and IEC 60947-2 ratings on the nameplate. It is halogen-free and silicon-free, which supports RoHS and REACH compliance declarations. The railway-design designation implies conformity with railway environmental standards.

MPN