Siemens 5SY4104-6CC11 — 1-Pole MCB (DIN Rail)

Siemens 5SY4104-6CC11 SENTRON MCB, 1P B-Curve 4A, 10kA

MPN5SY4104-6CC11

Siemens SENTRON miniature circuit breaker, 5SY4104-6CC11, 1-pole, B-curve, 4 A rated, 10 kA breaking capacity per EN 60898, for railway and industrial applications.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4104-6CC11 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY4104-6CC11 — Electrical & Protection
ParameterValue
Tripping characteristic classB
Rated value (EN 60898)10 kA
Energy limitation class3
Overvoltage categoryIII
5SY4104-6CC11 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY4104-6CC11 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

What it is and what it does

The Siemens SENTRON 5SY4104-6CC11 is a 1-pole miniature circuit breaker (MCB) with a B-curve tripping characteristic, rated 4 A at AC and a breaking capacity of 10 kA per EN 60898. That 10 kA rating means it can safely interrupt a fault current up to that level without welding its contacts or cascading the fault upstream — critical for selectivity in a distribution panel. The B-curve (3–5× In) is the standard choice for resistive and general-purpose loads; it will hold through a mild inrush but trip fast on a hard short.

Where it fits

This MCB snaps onto a DIN rail via the quick-assembly system, occupies a single modular width of 18 mm, and can be mounted in any position. The depth of 76 mm and installation depth of 70 mm mean it sits flush in a standard 18 mm wide slot with no extra clearance needed behind the rail. IP20 with connected conductors is normal for a panel-mounted breaker — it's protected against finger contact but expects to live inside an enclosure.

Frequently asked questions

What is the breaking capacity of 5SY4104-6CC11?

10 kA per EN 60898. That is the rated short-circuit breaking capacity for this B-curve 4 A MCB.

What is the operating temperature range for 5SY4104-6CC11?

-40 °C to +75 °C. Derate the continuous current above 40 °C per the manufacturer's table.

Where can I buy 5SY4104-6CC11?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN