Skip to main content
Siemens 5SY4104-8CC — 1-Pole MCB (DIN Rail)

Siemens 5SY4104-8CC SENTRON MCB, D Curve, 1-Pole, 10 kA

MPN5SY4104-8CC

Siemens SENTRON 5SY4104-8CC, 1-pole miniature circuit breaker, D tripping characteristic, 10 kA per EN 60898, 400 V AC, 1 MWU, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4104-8CC — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY4104-8CC — Electrical & Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY4104-8CC — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY4104-8CC — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SY4104-8CC is a 1-pole SENTRON miniature circuit breaker with a D tripping characteristic, rated 10 kA breaking capacity per EN 60898 at 400 V AC.

Key Ratings & Fit

Rated 400 V AC (single-phase or multi-phase) and 230 V single-phase supply, with a maximum DC operating voltage of 72 V. The 10 kA breaking capacity per EN 60898 covers most industrial panel secondary faults; for UL 1077 / CSA C22.2 No. 235 installations the rating is 5 kA. The combined terminal design (top and bottom) accepts both busbar and wire connections without separate adapters.

Environmental & Mechanical

Ambient temperature range -40 °C to 75 °C, with derating on humidity (max 95% at 55 °C, 55% at 70 °C, 35% at 75 °C). Halogen-free and silicon-free construction. Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz. Mechanical service life 10 000 operating cycles typical. Sealable for tamper-proof installations. IP20 with connected conductors — intended for enclosed panel mounting, not washdown.

Snap-on DIN rail mount, 18 mm width (1 MWU), 76 mm depth, 90 mm height, 70 mm installation depth. Any mounting position. Neutral conductor is not switched — single-pole design only.

Frequently asked questions

What is the breaking capacity of 5SY4104-8CC?

10 kA per EN 60898 at 400 V AC; 5 kA per UL 1077 and CSA C22.2 No. 235.

What tripping characteristic does this MCB have?

D characteristic — designed for loads with high inrush current such as motors, transformers, and welding equipment.

Where can I buy 5SY4104-8CC?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation is available for 5SY4104-8CC?

The part carries EN 60898 and UL 1077 / CSA C22.2 No. 235 ratings. It is halogen-free and silicon-free. Specific RoHS/REACH declarations are provided with the shipment.

MPN
5SY4104-8CC